نتایج جستجو برای: Low Voltage Ride Through

تعداد نتایج: 2486257  

2011
YONG LIAO HUI LI JUN YAO

The grid codes now require doubly fed induction generator (DFIG) wind turbines having the “low voltage ride-through (LVRT)” capability. However, a traditional DFIG with a partially rated back-to-back converter has inherent difficulties to ride through the grid faults, especially for the unbalanced grid faults. Modifications to the traditional DFIG configuration for ride-through have become nece...

Akbari, Ehsan ,

Abstract: With the growth of communities and the increasing need for electricity, and because of the many benefits of renewable energy sources, the wind turbine has become a completely commercial and inevitable process, with increasing penetration into the electricity grid. Distribution networks, on the other hand, are subject to fault that cause power fluctuations and outflow of wind units. In...

2014
A. D. Thirumoorthy

Wind power generation is increasing rapidly in India and wind integration with the grid is considered as a promising source of energy, Double Fed Induction Generator (DFIG) being the most commonly used wind turbine generator, when integrated with the grid show challenges during grid faults. This paper focuses on the challenges faced by DFIG during the occurrence of voltage sags and the Low Volt...

2014
Gustav Lammert Tobias Heß Maximilian Schmidt Peter Schegner Martin Braun

Faults in medium and high voltage grids lead to voltage sags in the low voltage level. Due to the voltage dip, distributed generators disconnect from the low voltage grid. Depending on the amount of disconnected generation, system stability could be compromised. With a dynamic grid support, distributed generators remain connected to the grid during faults, also called fault ride-through. Moreov...

In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...

Journal: :E3S web of conferences 2021

Based on the analysis of operation characteristics fault direct-drive permanent magnet wind turbine and existing protection strategies, in order to improve low-voltage capability turbine, a new coordinated control strategy for crossing is proposed this paper, which includes DC brake system unloading circuit, double second-order generalized integral phase-locked control, extracting positive nega...

2016
Subhashish Bhattacharya Mohammad Sameer Khan Mesut Baran Saima Khan Troy Nagle

KHAN, MOHAMMAD SAMEER. Analysis of Flyback-PV Inverter to Enable Low Voltage Ride-Through (LVRT) Operation During Grid Fault. (Under the direction of Dr. Subhashish Bhattacharya). Flyback based PV micro-inverter is a very popular low-cost solution for integrating the photovoltaic (PV) module to an AC grid. As the penetration level of these inverters in the grid is increasing, it may cause probl...