نتایج جستجو برای: Locking compression late

تعداد نتایج: 296453  

Journal: :the archives of bone and joint surgery 0
seyyed morteza kazemi bone joint and related tissue research center, akhtar hospital, shahid beheshti university of medical sciences, tehran, iran reza minaei bone joint and related tissue research center, akhtar hospital, shahid beheshti university of medical sciences, tehran, iran farshad safdari bone joint and related tissue research center, akhtar hospital, shahid beheshti university of medical sciences, tehran, iran ali keipourfard akhtar hospital, shahid beheshti university of medical sciences, tehran, iran rozhin forghani bone joint and related tissue research center, akhtar hospital, shahid beheshti university of medical sciences, tehran, iran alemeh mirzapourshafiei clinical research development center, babol university of medical sciences, babol, iran

background: there are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. in the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. methods: forty patients with valgus knee malalignment were randomly assigned to two equal numb...

  Background: There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. Methods: Forty patients with valgus knee malalignment were randomly assigned to two equal nu...

Journal: :Acta orthopaedica Belgica 2015
Ahmet Adnan Karaarslan Ahmet Karakaşli Tolga Karci Hakan Aycan Serhat Yildirim Erhan Sesli

The aim is to present our new method of compression, a compression tube instead of conventional compression screw and to investigate the difference of proximal locking screw bending resistance between compression screw application (6 mm wide contact) and compression tube (two contact points with 13 mm gap) application. We formed six groups each consisting of 10 proximal locking screws. On metal...

- Amarpal A. M. Pawde D. N. Madhu H. P. Aithal P. Kinjavdekar R. A. Ahmad,

Grade 1 open spiral fracture of left tibia in a 1.5 year-old horse was treated using a combination of 4.5 mm locking compression plate (LCP) and a dynamic compression plate applied in a neutralization manner. The open wound was managed postoperatively by regular dressing and lavage. Radiograph at 24 days post-treatment revealed callus formation and at two months complete bridging callus was obs...

2007
Aaron Johnson Aaron Joseph Johnson

Title of Document: HUMERAL FRACTURE FIXATION TECHNIQUES: A FEA COMPARISON OF LOCKING AND COMPRESSION TECHNIQUES WITH CADAVERIC PULLOUT COMPARISON OF CORTICAL COMPRESSION AND INTERNAL LOCKING SCREWS. Aaron Johnson, MS Mechanical Engineering, 2007 Directed By: Professor, Donald Barker, Mechanical Engineering Locking and non-locking humeral repair techniques provide different mechanical constructs...

2017
Wei Liu Lihui Yang Xiaochuan Kong Likun An Gang Hong Zicheng Guo Lei Zang

BACKGROUND Locking compress plate, as external fixator, is an attractive technique for distal tibial fracture treatment. But it still remains unclear whether the external LCP has sufficient stiffness. Thus, the present study aims to make a comprehensive evaluation of the stiffness of external locking compress plate when it is used as an external fixator in distal tibial fractures treatment. M...

Journal: :Journal of orthopaedic surgery 2008
S Agarwala S B Shah

PURPOSE To compare the results of staple versus locking compression plate fixation after closing wedge high tibial osteotomy. METHODS A group of 23 patients (24 knees) who underwent box high tibial osteotomy and staple fixation was compared with another group of 19 patients (22 knees) who underwent a similar procedure but with locking compression plate fixation. Both groups were followed up f...

Journal: :Injury 2011
T Schepers E M M Van Lieshout M R De Vries M Van der Elst

INTRODUCTION There is a growing use of locking compression plates in fracture surgery. The current study was undertaken to investigate the wound complication rates of locking versus non-locking plates in distal fibular fractures. PATIENTS AND METHODS During a 6-year study period all consecutive, closed distal fibular fractures treated with either a locking or a non-locking plate were included...

Journal: :Orthopedics 2015
Yu Fan Yue-Wang Li Hong-Bo Zhang Jian-Fei Liu Xiang-Min Han Xiao Chang Xi-Sheng Weng Jin Lin Bao-Zhong Zhang

Surgical fixation of humeral shaft fractures generally involves plating or nailing. It is unclear whether one method is more effective than the other. The aim of this study was to compare the results of the intramedullary nail and locking compression plate for the treatment of humeral shaft fractures. A total of 60 patients with humeral shaft fractures were randomized to undergo surgery with an...

Journal: :acta medica iranica 0
seyed behzad jazayeri sina trauma and surgery research center and student's scientific research center, tehran university of medical sciences, tehran, iran. and student’s scientific research center, tehran university of medical sciences, tehran, iran. masoumeh firouzi tissue repair laboratory, institute of biochemistry and biophysics (ibb), tehran university of medical sciences, tehran, iran. shayan abdollah zadegan sina trauma and surgery research center, tehran university of medical sciences, tehran, iran. and research centre for neural repair, tehran university of medical sciences, tehran, iran. niloufar saeedi sina trauma and surgery research center, tehran university of medical sciences, tehran, iran. elham pirouz sina trauma and surgery research center, tehran university of medical sciences, tehran, iran. mohsen nategh research centre for neural repair, tehran university of medical sciences, tehran, iran.

prior animal models have shown that rats sustaining 3-second immediate spinal cord compression had significantly better functional recovery and smaller lesion volumes than rats subjected to compression times of 1 hour, 6 hours, 3 weeks, and 10 weeks after spinal cord injury. we compare locomotor rating scales and spinal cord histopathology after 3 seconds and 10 minute compression times. . ten ...