نتایج جستجو برای: Linear attenuation coefficient

تعداد نتایج: 671039  

Journal: :journal of biomedical physics and engineering 0
p mehnati ph.d., department of medical physics, school of medicine, tabriz university of medical sciences, tabriz, iran m jafari tirtash m.s. student, department of medical physics, school of medicine, tabriz university of medical sciences, tabriz, iran m ghavami department of radiology, school of medicine, tabriz university of medical sciences, tabriz, iran

normal 0 false false false en-us x-none ar-sa aim: ct number (hu) and linear attenuation coefficient contain useful information which  can be determined during usual ct scanning for the prediction of breast cancerous cells existence based on hemoglobin concentration. methods: this study used breast phantom containing major and minor vessels with diameters of 10 and 5 mm, respectively. the major...

Journal: :journal of biomedical physics and engineering 0
f seif arak university of medical sciences m j tahmasebi-birgani ahvaz jundishapur university of medical sciences m r bayatiani arak university of medical sciences

background: in this study, a method for linear attenuation coefficient calculation was introduced. methods: linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. the calculation was done for cerrobend as a common radiotherapy modifier and mercury. results: the valu...

Background: In this study, a method for linear attenuation coefficient calculation was introduced.Methods: Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury.Results: The values...

2017
F. Seif M.J. Tahmasebi-Birgani M.R. Bayatiani

BACKGROUND In this study, a method for linear attenuation coefficient calculation was introduced. METHODS Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury. RESULTS The val...

Journal: :iranian journal of medical physics 0
rezvan khaldari medical physics department, medical school, tabriz university of medical sciences, tabriz, iran asghar mesbahi medical physics department, medical school, tabriz university of medical sciences, tabriz, iran. umit kara suleyman demirel university

introduction: globally, the need for radiotherapy as a part of cancer management increases every year. thus, the shielding for megavoltage radiotherapy rooms is of great importance. materials and methods: in the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using monte carlo method. the linear attenuation coefficient and th...

Journal: :Journal of X-ray science and technology 1998
P Hammersberg

Generally, computerised tomography (CT) is an X-ray based non-destructive testing method that was developed for medical purposes in the seventies and introduced for industrial applications during the eighties. CT produces maps of the X-ray linear attenuation coefficient of an object’s interior; presented either as cross section images (two-dimensional CT) or as volume information (three-dimensi...

C. Olaru, G.V. Ormenisan, M. Zadehrafi, S.A. Ciobanu,

Background: Lead glass has a wide variety of applications in radiation protection. This study aims to investigate some characteristics of lead glass such as the γ-ray energy-dependent mass and linear attenuation coefficients, the half-value layer thickness, and the absorbed dose distribution for specific energy. Materials and Methods: The attenuation parameters of different lead glass types aga...

2012
Folorunso O. Ogundare Samuel A. Ogundele Olumide O. Akerele Fatai A. Balogun

The ability of concrete to attenuate ionizing radiation intensity is assessed using its linear or mass attenuation coefficient. In this work, the broad-beam linear and mass attenuation coefficients of different types of soils and cements used for making concrete were measured at different photon energies (60-1333 keV), nearly spanning the diagnostic photon energy range, using a NaI detector. Th...

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید