نتایج جستجو برای: Lateral Resisting System

تعداد نتایج: 2337556  

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه سیستان و بلوچستان 1390

seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...

2013
Asif Hameed Imran Azeem Asad-ullah Qazi Burhan Sharif Noor Muhammad Khan

The race towards new heights and architecture has not been without challenges. Tall structures have continued to climb higher and higher facing strange loading effects and very high loading values due to dominating lateral loads. The design criteria for tall buildings are strength, serviceability, stability and human comfort. But the factors govern the design of tall and slender buildings all t...

2012
Mohammad AlHamaydeh Sherif Yehia Nader Aly Ammar Douba

Four design alternatives for lateral force-resisting systems of tall buildings in Dubai, UAE are presented. Quantitative comparisons between the different designs are also made. This paper is intended to provide different feasible lateral systems to be used in Dubai in light of the available seismic hazard studies of the UAE. The different lateral systems are chosen in conformance with the Inte...

Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...

An innovative type called "butterfly-shaped links steel plate shear wall (BLSPSW)" was proposed as a lateral load resisting system. In this novel system, by creating butterfly-shaped links in the four sides of the web plate, the lateral load resisting mechanism is not the development of a diagonal tension field on the web plate (similar to Conventional SPSWs), but the capacity of the system is ...

Moment resisting frames as one of the conventional lateral load resisting systems in buildings suffer from some limitations including code limitations on minimum span-to-depth ratio to ensure the formation of plastic hinges with adequate length at beam ends. According to seismic codes, in ordinary steel moment resisting frames the minimum span-to-depth ratios should be limited to 5 and in speci...

Journal: :Engineering, Technology & Applied Science Research 2019

Journal: :International Journal of Innovative Research in Computer Science & Technology 2020

In this study, the progressive collapse potential of seismically designed steel plate shear wall (SPSW) systems is investigated using the alternate path method, and their performances are compared with those of the conventional special moment frame (SMF) systems. Nonlinear static and dynamic analyses are conducted to follow the progressive collapse of the structures, and their ability of absorb...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید