نتایج جستجو برای: Keywords: Motion correction

تعداد نتایج: 2309005  

Journal: :asia oceania journal of nuclear medicine and biology 0
michael masoomi 1-department of nuclear medicine, farwaniya hospital, kuwait anne h mclean 2-nuclear medicine physics, queen alexandra hospital, portsmouth, uk yassine bouchareb 3-clinical physics, barts health, nhs trust, uk. will ryder 4-faculty of health science, university of sydney, sydney, australia andy robinson 5-the harley street clinic, london, uk

abstractobjective: to investigate the impact of respiratory motion on localization, and quantification lung lesions for the gross tumour volume utilizing an in-house developed auto3dreg programme and dynamic nurbs-based cardiac-torso digitised phantom (ncat). methods: respiratory motion may result in more than 30% underestimation of the suv values of lung, liver and kidney tumour lesions. the m...

Journal: :archives of cardiovascular imaging 0
bernhard bischoff institute for clinical radiology, ludwig-maximilians-university hospital munich, 80337 munchen, germany; dzhk (german centre for cardiovascular research), partner site munich heart alliance, munich, germany; institute for clinical radiology, ludwig-maximilians-university hospital munich, 80337 munchen, germany. tel: +49-89440044858 lucas l geyer institute for clinical radiology, ludwig-maximilians-university hospital munich, 80337 munchen, germany; dzhk (german centre for cardiovascular research), partner site munich heart alliance, munich, germany maximilian f reiser institute for clinical radiology, ludwig-maximilians-university hospital munich, 80337 munchen, germany; dzhk (german centre for cardiovascular research), partner site munich heart alliance, munich, germany ullrich g mueller lisse institute for clinical radiology, ludwig-maximilians-university hospital munich, 80337 munchen, germany; dzhk (german centre for cardiovascular research), partner site munich heart alliance, munich, germany

background motion artifacts that degrade image quality of coronary ct angiography (ccta) in patients with high heart rates may be reduced with specific automatic motion correction algorithms (amc). conclusions ccta image quality improves significantly with amc in patients with high heart rates and reduces the proportion of non-diagnostic examinations. results mean heart rate during ccta was 61 ...

رجبی, حسین, شیرازی, علیرضا , صادقی, مهدی, محمدی, ایرج, پولادیان, مجید ,

Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...

Arman Rahmim

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

Journal: :iranian journal of nuclear medicine 2005
arman rahmim

with the arrival of increasingly higher resolution pet systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. in this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. for the first type of motion...

Journal: :مجله دانشکده پزشکی اصفهان 0
منوچهر امیری دوان مهدی سنبلستان حمید رضا حسنانی حمید رضا ابطحی

introduction carhart's notch (cn) is a major audiometric criterion for diagnosis of otosclerosis; it is an abnormal audiometric pattern due to fixation of stapes and relative reduction in perilymphatic motion. methods 130 patients (146 diseased ears) were evaluated in this study. audiometric tests were performed for each patient 2 weeks before and 6 month after surgery, and the average decline ...

2015
Elisa Ficarra Andrea Acquaviva Enrico Macii

Arterial Spin Labelling (ASL) is a perfusion MRI technique with tremendous applications in the study of biological markers and prognostic factors of brain tumors and in the assessment of neural diseases; moreover, it is completely non-invasive as it uses the magnetically inverted blood of the patient as an endogenous tracer. Unfortunately this powerful method is only viable in very limited cond...

Journal: :Conference SENATIK STT Adisutjipto Yogyakarta 2019

Journal: :iranian journal of radiation research 0
y.l. kim department of radiology, choonhae college of health science, ulsan 689-784, south korea t.s. suh department of radiology, choonhae college of health science, ulsan 689-784, south korea b.y. choe department of radiology, choonhae college of health science, ulsan 689-784, south korea b.o. choi department of radiation oncology, seoul st. mary’s hospital, the catholic university, seoul 137-701, south korea j.b. chung department of radiadion oncology, seoul national university bundang hospital, seongnam 463-707, south korea j.w. lee department of radiation oncology, konkuk university medical center, seoul 143-729, south korea

background: dose calculation algorithms play a very important role in predicting the explicit dose distribution. we evaluated the percent depth dose (pdd), lateral depth dose profile, and surface dose volume histogram in inhomogeneous media using calculation algorithms and inhomogeneity correction methods. materials and methods: the homogeneous and inhomogeneous virtual slab phantoms used in th...

Journal: :iranian journal of nuclear medicine 2007
kourosh ebrahim nejad gorgi hossein rajabi ebrahim hajizadeh faraz kalantari hadi taleshi

introduction: there are several technical features that make pet an ideal device for the noninvasive evaluation of cardiac physiology. organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac pet imaging. these motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent lesion size and shape and reduci...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید