abstractobjective: to investigate the impact of respiratory motion on localization, and quantification lung lesions for the gross tumour volume utilizing an in-house developed auto3dreg programme and dynamic nurbs-based cardiac-torso digitised phantom (ncat). methods: respiratory motion may result in more than 30% underestimation of the suv values of lung, liver and kidney tumour lesions. the m...
background motion artifacts that degrade image quality of coronary ct angiography (ccta) in patients with high heart rates may be reduced with specific automatic motion correction algorithms (amc). conclusions ccta image quality improves significantly with amc in patients with high heart rates and reduces the proportion of non-diagnostic examinations. results mean heart rate during ccta was 61 ...
Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
with the arrival of increasingly higher resolution pet systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. in this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. for the first type of motion...
introduction carhart's notch (cn) is a major audiometric criterion for diagnosis of otosclerosis; it is an abnormal audiometric pattern due to fixation of stapes and relative reduction in perilymphatic motion. methods 130 patients (146 diseased ears) were evaluated in this study. audiometric tests were performed for each patient 2 weeks before and 6 month after surgery, and the average decline ...
Arterial Spin Labelling (ASL) is a perfusion MRI technique with tremendous applications in the study of biological markers and prognostic factors of brain tumors and in the assessment of neural diseases; moreover, it is completely non-invasive as it uses the magnetically inverted blood of the patient as an endogenous tracer. Unfortunately this powerful method is only viable in very limited cond...
background: dose calculation algorithms play a very important role in predicting the explicit dose distribution. we evaluated the percent depth dose (pdd), lateral depth dose profile, and surface dose volume histogram in inhomogeneous media using calculation algorithms and inhomogeneity correction methods. materials and methods: the homogeneous and inhomogeneous virtual slab phantoms used in th...
introduction: there are several technical features that make pet an ideal device for the noninvasive evaluation of cardiac physiology. organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac pet imaging. these motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent lesion size and shape and reduci...