نتایج جستجو برای: Inter-Story Drifts

تعداد نتایج: 158338  

A. R. Habibi, N. Khaledy, P. Memarzadeh,

Design of blast resistant structures is an important subject in structural engineering, attracting the attention of governments, researchers, and engineers. Thus, given the benefits of optimization in engineering, development and assessment of optimization methods for optimum design of structures against blast is of great importance. In this research, multi-objective optimization of steel momen...

The present study assesses the seismic performance of steel moment resisting frames (SMFs) retrofitted with different bracing systems. Two structural configurations were utilized: ordinary concentrically braces (OCBFs), buckling-restrained braces (BRBFs). A 7-story and 18-story steel perimeter SMFs were designed with insufficient lateral stiffness to satisfy code drift limitations in high seism...

Journal: :journal of rehabilitation in civil engineering 2014
gholamreza abdollahzadeh heidar farzi-bashir mohammadreza banihashemi

the present study assesses the seismic performance of steel moment resisting frames (smfs) retrofitted with different bracing systems. two structural configurations were utilized: ordinary concentrically braces (ocbfs), buckling-restrained braces (brbfs). a 7-story and 18-story steel perimeter smfs were designed with insufficient lateral stiffness to satisfy code drift limitations in high seism...

Journal: :مهندسی عمران فردوسی 0
مجتبی رضوی محمدرضا شیدایی

zipper braced frames are an innovative bracing system for steel structures. conventional inverted-v-braced frames exhibit a design problem arising from the unbalanced vertical force generated by the lower story braces when one of them buckles. this adverse effect can be mitigated by adding zipper columns or vertical members connecting the intersection points of the braces above the first floor....

2012
J. Zhou G. B. Bu K. N. Li

Inter-story drift is an important indicator of structural behaviour in performance-based seismic analysis. This paper describes the definition and contents of the inter-story drift. Existing calculation methods for harmful and harmless inter-story drift are revisited first. Their advantages and shortcomings are compared. Finally, the generalized shear deformation of region, which seems to be su...

Hasan Aghbarati M. Askari,

Near-fault ground motions have caused very much damage in the vicinity of seismic sources during recent earthquakes. It is well known that under specific circumstances, intensive ground shakings near fault ruptures may be characterized by short-duration impulsive motions. This pulse-type motion is generally particular to the forward direction, where the fault rupture propagates towards the site...

Journal: :journal of structural engineering and geo-techniques 2012
m. askari hasan aghbarati

near-fault ground motions have caused very much damage in the vicinity of seismic sources during recent earthquakes. it is well known that under specific circumstances, intensive ground shakings near fault ruptures may be characterized by short-duration impulsive motions. this pulse-type motion is generally particular to the forward direction, where the fault rupture propagates towards the site...

2007
Maria I. Todorovska Mihailo D. Trifunac

The former Imperial County Services Building was a six-story reinforced concrete structure in the El Centro, California, severely damaged by the 1979 Imperial Valley earthquake. It represents a rare case of an instrumented building that has been damaged, and thus can serve as a full-scale benchmark to evaluate and further develop structural health monitoring methods. This paper presents an anal...

2015
Arshad K. Hashmi

The paper presents a plastic analysis procedure based on the energy balance concept for performance based seismic retrofit of multi-story multi-bay masonry infilled reinforced concrete (R/C) frames with a ‘soft’ ground story using passive energy dissipation (PED) devices with the objective of achieving a target performance level of the retrofitted R/C frame for a given seismic hazard level at t...

2014
Jong Wan Hu

Base isolation has been used as one of the most wildly accepted seismic protection systems that should substantially dissociate a superstructure from its substructure resting on a shaking ground, thereby sustainably preserving entire structures against earthquake forces as well as inside non-structural integrities. Base isolation devices can operate very effectively against near-fault (NF) grou...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید