This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...
In this paper, a novel control strategy for a Shunt Active Power Filter (shunt-APF) is proposed. In the proposed control strategy which is based on a new application of the instantaneous reactive power theory, the current injected by the shunt-APF is capable of compensation for the reactive component, the harmonic components and also unbalance of the load current. In this strategy, the shunt-AP...
In order to detect grid harmonic and reactive current precisely and real time, this paper arrived at a method of harmonic and reactive current real-time detection applied to active power filter based on the three-phase circuit instantaneous reactive power theory. With Matlab simulation software, researches on simulation of harmonic detection means are carried out, and an analysis of the simulat...
This paper gives a new insight into the concept of load compensation using shunt active filter (SAF) under ideal and non-ideal source voltage conditions. A novel approach based on an improved instantaneous active and reactive current component method is proposed. The performance of the proposed control strategy has been compared with instantaneous reactive power theory, symmetrical component th...
Magnetic Resonance Imaging allows for minimally invasive targeting and thermal ablation of tumors while monitoring the temperature distribution. Conventional MR thermometry procedures are hampered by either low accuracy or high sensitivity to motion artifacts due to the use of a reference temperature image. A new, dual-echo technique has been developed to obtain the temperature distribution wit...
electric arc furnace (eaf) is one of the largest loads in electric power systems. it is highly time varying and nonlinear. its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. on the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in eaf. to this end flexible ac transmission systems (facts) techn...
Abstract— The active power filters eliminates the harmonic distortion caused by non-linear loads and improves the filtering efficiency performance when compared with the passive filters. This paper inspects about the analysis and simulation of a three phase four wire shunt active power f ilter under unbalanced and distorted load conditions. Current harmonic compensation is achieved by the imple...
This paper deals with the current space-vector decomposition in three-phase, three-wire systems on the basis of some case studies. We propose four components of the current spacevector in terms of DC and AC components of the instantaneous active and reactive powers. The term of supplementary useless current vector is also pointed out. The analysis shows that the current decomposition which resp...