نتایج جستجو برای: Hysteretic energy
تعداد نتایج: 668326 فیلتر نتایج به سال:
The variation of earthquake input energy with characteristics of various structural systems, particularly in hysteretic states, has not been studied to such extent that creates enough con-fidence for proposing energy-based design criteria. In this paper, at first, based on a somehow new insight into the concept of earthquake input energy, two concepts of ‘Received Energy’ (ERec) and ‘Returned E...
the present article seek to investigate the function of elliptical steel damper function in steel frames seismic resisting. the elliptical damper is a kind of earthquake energy dissipater in structure which acts based on the steel yielding feature. thus, this damper in frame lateral displacement mechanism is expected to have a satisfying hysteretic behavior in terms of energy absorption is on a...
Numerical Computation of Rolling Resistance Based on the Result of Tire/Road Static Contact Analysis
Among various dissipating mechanisms, the viscoelastic effect of rubber material on creation of rolling resistance is responsible for 10-33% dissipation of supplied power at the tire/road interaction surface. So, evaluating this kind of loss is very essential in any analysis concerned with improving the fuel consumption of vehicles and resultantly energy savage. Hysteretic loss is a fraction of...
The coupling beam damper is a fundamental energy dissipation component in coupling shear wall structures that directly influences the performance of the shear wall. Here, we proposed a two-fold design method that can give better energy dissipation performance and hysteretic behavior to coupling beam dampers. First, we devised four in-plane yielding coupling beam dampers that have different open...
Hysteretic energy dissipation in conventional structural configurations can be undesirable if it is achieved by the damage of primary structural members. Ideally, this hysteretic energy dissipation should occur in structural elements that are “disposable” (i.e., structural fuses that can be replaced without disturbance to the main system, just like real fuses). Much work has been accomplished o...
In order to improve the energy dissipation of the masonry infilled frame structure while decreasing the stiffening and strengthening effects of the infill panels, a new dry stacked panel (DSP) semi-interlocking masonry (SIM) infill panel has been developed. In this paper, the material properties of DSP and a traditional unreinforced masonry (URM) panel have been evaluated experimentally. A seri...
In contrast to nailed connections, little research has been done on bolted connections using a reversed cyclic loading scheme, although cyclic loading provides important information about energy absorption and damping properties, which is essential when analyzing seismic performance. Dowrick (1986) noted that the hysteretic characteristics for the primary connection of a subassembly govern its ...
hysteretic dampers as the most practical passive control methods have improved the seismic performance of steel structures through energy dissipation induced by large inelastic deformations. among them in this paper, kbf (knee braced frames), a special form of braced frames having a diagonal brace connected to a knee element instead of beam-column joint, is investigated. in such systems, the kn...
an experimental study on frp strengthened reinforced concrete frames under simulated seismic loading
the current study focuses on the experimental investigation of frp strengthening of rc portal frame subjected to combined vertical and horizontal loads. the main target of this research is to enhance the proposed structural properties that the rc portal frame had before the seismic occurrences by providing retrofitting of both columns and joints with more deformation capacity. the effect of var...
The present article seek to investigate the function of elliptical steel damper function in steel frames seismic resisting. The elliptical damper is a kind of earthquake energy dissipater in structure which acts based on the steel yielding feature. Thus, this damper in frame lateral displacement mechanism is expected to have a satisfying hysteretic behavior in terms of energy absorption is on a...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید