نتایج جستجو برای: Heat Ventilation and Air Conditioning

تعداد نتایج: 16930568  

Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...

2014
Jan Wrobel Gerhard Schmitz JAN WROBEL GERHARD SCHMITZ

A research project of the Hamburg University of Technology realizes an open cycle desiccant assisted air conditioning system based on renewable heat sources e.g. solar thermal and heat sinks e.g. shallow geothermal energy. Both advantages of the open cycle process are taken into account, the possible use of a heat sink at higher temperatures and the use of low calorific heat. Moreover, the tota...

Exergy analysis emboldens in cases that all the inefficiencies and bottlenecks to improve energy systems are to be addressed. In this study, a novel vapor compression air dehumidifier integrated with an auxiliary heat exchanger in series arrangement with the main condenser in order to mitigate the reheat coil, and an extra mixing box to recover the ventilated air heat has been introduced. A com...

2016
Lian Zhang Yu Feng Zhang Nyuk Hien Wong

In this research, the application of heat pipes in the air handler dedicated to decoupling dehumidification from cooling to reduce energy consumption was simulated and investigated by simulations and experimental studies. The cooling load profiles and heat pipes with effectiveness of 0.45 and 0.6, respectively, were evaluated in achieving the desired space conditions and calculated hour by hour...

Journal: :E3S web of conferences 2021

An improved optimization adjustment strategy for building heating ventilation and air conditioning (Heating Ventilation Air Conditioning, HVAC) is proposed. The energy consumption model of heating/refrigeration established by using the instantaneous balance heat, then optimal operation HVAC based on weather forecast data constructed in range user temperature comfort. Finally, MATLAB TRNSYS simu...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی اصفهان 1389

run-out-table (rot) is located between last finishing stand and down coiler in a hot strip mill. as the hot steel strip passes from rot, water jets impact on it from top and bottom and strip temperature decreases approximately from 800-950 °c to 500-750°c. the temperature history that strip experience while passing through rot affects significantly the metallurgical and mechanical properties, s...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تبریز 0

a semi-empirical mathematical model for predicting physical part of ignition delay period in the combustion of direct - injection diesel engines with swirl is developed . this model based on a single droplet evaporation model . the governing equations , namely , equations of droplet motion , heat and mass transfer were solved simultaneously using a rung-kutta step by step unmerical method . the...

One of basic principles in designing treatment environments is to design air conditioning/ventilation system proportionate to environment. Essentially, appropriate air conditioner in treatment spaces must bear the following capabilities: providing healthy and clean air, reducing the concentration of pollutants produced in the atmosphere, emission of pollutants and impeding their spread in exter...

2009
Y. H. Yau

In the operating theatre, where exhausted air is not permitted to be re-circulated, maintaining the conditions could be tedious on the HVAC systems and found to be energy inefficient. This research will look into the potential energy savings using heat recovery devices in treating the ventilation air, without compromising the occupants’ thermal comfort and health in the conditioned space. For t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید