Journal: :The Journal of trauma 2008
Elizabeth A Mann Jose Salinas Heather F Pidcoke Steven E Wolf John B Holcomb Charles E Wade

BACKGROUND A point-of-care (POC) glucometer (G1) used for critical care at our institution is inaccurate in the presence of low hematocrit (HCT) values. The purpose of this study was to analyze error rates of three additional POC glucometer brands and determine mathematical correction formulas for each. METHODS Blood samples (n = 196) from a cohort of surgical, trauma, medical, cardiothoracic...

Journal: :Work 2012
Christopher B Mayhorn Eric D Carpenter

The elderly are at an increased risk for being diagnosed with diabetes. While previous studies have examined technique errors when a patient used his or her current blood glucometer or a single novel glucometer, no study has measured errors as a patient transferred to using a second, novel experimental glucometer. Results support findings that older adults perform more slowly and less accuratel...

Journal: :Acta medica Iranica 2014
Fatemeh Nayeri Mamak Shariat Hamid Modarres Mousavi Behbahani Padideh Dehghan Bita Ebrahim

Hypoglycemia is considered as a serious risk factor in neonates. In the majority of cases, it occurs with no clinical symptoms. Accordingly, early diagnosis is extremely imperative, which can also lead to less morbidity and mortality. The aim of this study was to assess the importance of screening blood glucose using glucometer (known as a quick and cost-effective diagnostic test) in comparison...

Journal: :Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia 2005
Rudolf Chlup Martin Payne Jana Zapletalová Stanislav Komenda Blanka Doubravová Martina Reznícková Ludmila Chlupová Pavel Seckar

The aim of this prospective clinical study was to compare the results of B-glucose estimations performed simultaneously on glucometer Advance (with Micro-draw strips) and Optium (G3 strips) by lay healthy volunteers under non-standardized conditions of everyday life, to assess the difficulties dealing with lay-handling of these systems and to demonstrate the possibilities of the software Glucob...

Journal: :JPMA. The Journal of the Pakistan Medical Association 1998
H A Usmani I I Khan F H Mughal

The Precision Quantum-in-dium (Q.I.D.) Glucometer was used to determine the glucose concentrations of 38 human blood samples. The same samples were also run on the OPERA Chemistry Autoanalyzer 2010 system. More than 44% of the glucometer reports had a difference of greater than 15% from the respective autoanalyzer reports. The calibration of the glucometer could be the source of the error and a...

Journal: :Diabetes care 2000
J Girouard J C Forest J Massé M Leroux N C Bradburn T C Noblet J O Joynes J Baum

OBJECTIVE To evaluate the clinical performance of the Glucometer Elite XL Diabetes Care System in neonatal settings using a multicenter study RESEARCH DESIGN AND METHODS A total of 388 blood specimens from 333 neonates were included in the study. A capillary or arterial sample was analyzed for determination of glucose with the Glucometer Elite XL system by an attending trained nurse. Through ...

Journal: :Emergency medicine journal : EMJ 2005
R Boyd B Leigh P Stuart

OBJECTIVES To determine the mean difference and correlation between capillary and venous bedside glucose estimation in comparison to laboratory blood glucose analysis in emergency department (ED) patients. METHODS Blood glucose levels were synchronously analysed using a bedside blood glucometer on capillary and venous derived samples from consenting ED patients aged >12 years. The venous samp...

2015
Mehmet Nuri Özbek Murat Öcal Sibel Tanrıverdi Birsen Baysal Ahmet Deniz Kahraman Öncel Hüseyin Demirbilek

A number of factors may lead to inaccuracy in measurement of capillary blood glucose with a glucometer. Measurement of other carbohydrate molecules such as galactose and fructose along with glucose can potentially be a cause of error. We report a newborn patient who was referred to our hospital with conjugated bilirubinemia, hepatomegaly and high capillary blood glucose levels measured with a g...

Journal: :Analytical chemistry 2016
Chien-Chung Wang Jonathan W Hennek Alar Ainla Ashok A Kumar Wen-Jie Lan Judy Im Barbara S Smith Mengxia Zhao George M Whitesides

This paper describes the design and fabrication of a "pop-up" electrochemical paper-based analytical device (pop-up-EPAD) to measure beta-hydroxybutyrate (BHB)-a biomarker for diabetic ketoacidosis-using a commercial combination BHB/glucometer. Pop-up-EPADs are inspired by pop-up greeting cards and children's books. They are made from a single sheet of paper folded into a three-dimensional (3D)...

Journal: :Journal of Ayub Medical College, Abbottabad : JAMC 2007
Ayaz Baig Imran Siddiqui Abdul Jabbar Syed Iqbal Azam Salman Sabir Shahryar Alam Farooq Ghani

BACKGROUND To determine the accuracy, turnaround time and cost effectiveness of bedside monitoring of blood glucose levels by non-laboratory health care workers and centralized testing of blood glucose by automated analyzer in a tertiary care hospital. METHODS The study was conducted in Section of Chemical Pathology, Department of Pathology and Microbiology and Section of Endocrinology Depart...