Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
superconductor fault current limiter (sfcl) is an effective device to suppress high fault currents. this paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. appropriate location and type of the limiters in a hv substation is selected by a qualitative approach based on the equal area criterion. study system is simulated by...
Superconductor fault current limiter (SFCL) is an effective device to suppress high fault currents. This paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. Appropriate location and type of the limiters in a HV substation is selected by a qualitative approach based on the equal area criterion. Study system is simulated by...
This paper proposes an exhaustive study about the performance analysis of Doubly Fed Induction (DFIG) under abnormal condition. Now a day, majority of power network countenance the problem of over current and grid connectivity issues. SFCL (Superconducting Fault Current Limiter), which have the competence to limit the fault current and protect the equipments from damage. SMES (Superconducting M...
in this paper, the impacts of installing superconducting fault current limiter (sfcl)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (dg). among various sfcls, the hybrid type with a superconducting element in parallel with a current limiting reactor (clr) is selected. this is more effective than resisto...
In this paper, transient stability improvement using bridge type fault current limiter (FCL) is presented in single machine infinite bus (SMIB) system with a double circuit transmission line. Three single-phase sets of the proposed FCL are installed at the beginning of feeder. The proposed FCL inserts an inductance and a resistance in the fault current pass. The insertion inductance and resista...