Journal: :iranian journal of radiology 0
xianchun zeng department of radiology, guizhou provincial people’s hospital, guiyang, china; department of ct, the first affiliated hospital of kunming medical university, kunming, china shaolei kang department of ct, the first affiliated hospital of kunming medical university, kunming, china rongpin wang department of radiology, guizhou provincial people’s hospital, guiyang, china dan han department of ct, the first affiliated hospital of kunming medical university, kunming, china; department of ct, the first affiliated hospital of kunming medical university, kunming, p. o. box: 650032, china. tel: +86-87165324888, fax: +86-87165324888 yong wang department of ct, the first affiliated hospital of kunming medical university, kunming, china shiping yang department of ct, the first affiliated hospital of kunming medical university, kunming, china

conclusion safire reconstruction provided better coronary image quality and displayed the number, morphology, and surrounding lumen of calcium plaques more accurately than traditional fbp reconstruction, with safire3 achieving the best results. results the subjective ratings of image quality using safire1–safire5 reconstructions were significantly higher than those using fbp, with safire3 achie...

Introduction: Quantitative evaluation is recommended to improve diagnostic ability and serial assessment of dopamine transporter (DAT) density scans. We decided to compare the ordered subsets expectation-maximization (OSEM) with filtered back-projection (FBP), and to investigate the impact of different iteration and cut-off frequencies on SBR values. Methods</stro...

Amin Zonoozi Kamran Aryana Mehdi Momennezhad, Mohsen Hajizadeh Seyed Rasoul Zakavi, Vahid Reza Dabbagh Kakhki,

Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...

Journal: :iranian journal of nuclear medicine 2004
seyed rasoul zakavi mohsen hajizadeh amin zonoozi mehdi momennezhad kamran aryana

introduction: motion of the patient during myocardial perfusion spect could potentially results in false perfusion defects. the effect of different reconstruction methods on these artifacts is not studied. clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. this study...

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

Journal: :Radiology 2011
Matthias Renker John W Nance U Joseph Schoepf Terrence X O'Brien Peter L Zwerner Mathias Meyer J Matthias Kerl Ralf W Bauer Christian Fink Thomas J Vogl Thomas Henzler

PURPOSE To prospectively compare traditional filtered back projection (FBP) and iterative image reconstruction for the evaluation of heavily calcified arteries with coronary computed tomography (CT) angiography. MATERIALS AND METHODS The study had institutional review board approval and was HIPAA compliant. Written informed consent was obtained from all patients. Fifty-five consecutive patien...

2017
Xiaoyi Liu Lei Chen Weiwei Qi Yan Jiang Ying Liu Miao Zhang Nan Hong

This study was aimed to evaluate the image quality and lacunar lesion detection of thin-slice brain computed tomography (CT) images with different reconstruction algorithms, including filtered back projection (FBP), hybrid iterative reconstruction (HIR), and iterative model reconstruction (IMR) by comparison of routine slice images with FBP reconstruction. Sixty-one patients underwent noncontra...

2006
Ying Chen Joseph Y. Lo Jay A. Baker James T. Dobbins

Breast cancer is a major problem and the most common cancer among women. The nature of conventional mammography makes it very difficult to distinguish a cancer from overlying breast tissues. Digital Tomosynthesis refers to a three-dimensional imaging technique that allows reconstruction of an arbitrary set of planes in the breast from limited-angle series of projection images as the x-ray sourc...

Journal: :iranian journal of radiology 0
hyeon-sik kim department of nuclear medicine, chonnam national university hwasun hospital, hwasun, korea byeong-il lee korea photonics technology institute, gwangju, korea ju han kim department of cardiology, chonnam national university hospital, gwangju, korea hee-seung bom department of nuclear medicine, chonnam national university hwasun hospital, hwasun, korea dong-yeon kim department of nuclear medicine, chonnam national university hwasun hospital, hwasun, korea; department of nuclear medicine, chonnam national university hwasun hospital, hwasun, korea. tel: +82-61-3798476, fax: +82-61-3798455, e-mail:; dong-yeon kim, department of nuclear medicine, chonnam national university hwasun hospital, hwasun, korea. tel: +82-613797262, fax: +82-613797281 jung-joon min department of nuclear medicine, chonnam national university hwasun hospital, hwasun, korea; department of nuclear medicine, chonnam national university hwasun hospital, hwasun, korea. tel: +82-61-3798476, fax: +82-61-3798455, e-mail:; dong-yeon kim, department of nuclear medicine, chonnam national university hwasun hospital, hwasun, korea. tel: +82-613797262, fax: +82-613797281

conclusion osem3d may provide better image quality and higher contrast than other methods for small animal imaging with the new myocardial imaging agent, [18f] fptp. results the location and size of myocardial infarction on pet images correlated closely with that observed with ttc staining. among the four reconstruction methods, osem3d provided the best assessment of infarct size (r2 = 0.994, p...

Journal: :asia oceania journal of nuclear medicine and biology 0
akira maebatake division of medical quantum sciences, department of health sciences, graduate school of medical sciences, kyushu university, fukuoka, japan ayaka imamura radiological science course, department of health sciences, school of medicine, kyushu university, fukuoka, japan yui kodera radiological science course, department of health sciences, school of medicine, kyushu university, fukuoka, japan yasuo yamashita division of radiology, department of medical technology, kyushu university hospital, fukuoka, japan kazuhiko himuro division of radiology, department of medical technology, kyushu university hospital, fukuoka, japan shingo baba department of clinical radiology, graduate school of medical sciences, kyushu university, fukuoka, japan

objective(s): the aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (dat) single-photon emission computed tomography (spect). the results were compared between filtered back projection (fbp) and different attenuation correction (ac) methods.methods: an anthropomorphic striatal phant...