نتایج جستجو برای: External radial pressure

تعداد نتایج: 644055  

In this paper, exact closed-form solutions for displacement and stress components of thick-walled functionally graded (FG) spherical pressure vessels are presented. To this aim, linear variation of properties, as an important case of the known power-law function model is used to describe the FG material distribution in thickness direction. Unlike the pervious studies, the vessels can have arbit...

Journal: :anesthesiology and pain medicine 0
andrzej krol department of anaesthesia and chronic pain service, st georges hospital, london, united kingdom; consultant anesthetist in department of anaesthesia and chronic pain service, st georges hospital, london sw17 0re, united kingdom. tel: +44-2086721255, fax: +44-2087253135 matthew szarko st george’s university of london, london, united kingdom arber vala st george’s university of london, london, united kingdom jose de andres department of anaesthesia critical care and pain management, school of medicine, university of valencia, general university hospital, valencia, spain

conclusions obtained results demonstrate significant differences between intraneural and perineural injection pressures in the median, ulnar, and radial nerves. intraneural injection pressures show low specificity but high sensitivity suggesting that pressure monitoring might be a valuable tool in improving the safety and efficacy of peripheral nerve blockade in regional anesthesia. peripheral ...

Journal: :physiology and pharmacology 0
rafati rafati tarbiat modares university manijhe mokhtari-dizaji tarbiat modares university hajir saberi tehran medical sciences university hosein chegini

instruction: measurement of brachial artery diameter variation by ultrasound methods has commonly been used to test the endothelial function. it is known that the artery diameter is increased by flow stimulation. therefore in the present study, the effect of external obstruction, as flow stimulation, on the radial strain of the brachial artery was assessed. also the biomechanical behavior of th...

F. Barati, H. Ghaffari Some’e H. Mahbadi,

In this paper, the problem of calculating the stress intensity factor (SIF) for an orthotropic thick-walled cylinder with a small radial crack subject to internal pressure is considered. The crack is assumed to be an edge crack on the external radius of the cylinder. The stress intensity factor is calculated by superposition of an uncracked cylinder with uniform stress distribution and a cylind...

Journal: :iranian journal of mechanical engineering transactions of the isme 2013
h. ghaffari some’e f. barati h. mahbadi

in this paper, the problem of calculating the stress intensity factor (sif) for an orthotropic thick-walled cylinder with a small radial crack subject to internal pressure is considered. the crack is assumed to be an edge crack on the external radius of the cylinder. the stress intensity factor is calculated by superposition of an uncracked cylinder with uniform stress distribution and a cylind...

Hajir Saberi, Hosein Chegini, Manijhe Mokhtari-Dizaji, Rafati Rafati,

Instruction: Measurement of brachial artery diameter variation by ultrasound methods has commonly been used to test the endothelial function. It is known that the artery diameter is increased by flow stimulation. Therefore in the present study, the effect of external obstruction, as flow stimulation, on the radial strain of the brachial artery was assessed. Also the biomechanical behavior of...

Journal: :Physical review letters 2004
P Puech H Hubel D J Dunstan R R Bacsa C Laurent W S Bacsa

We have examined the stability of double wall carbon nanotubes under hydrostatic pressures up to 10 GPa. The tangential optical phonon mode observed by inelastic light scattering is sensitive to the in-plane stress and splits into a contribution associated with the external and internal tube. While the pressure coefficient from the external tube is the same as in single wall carbon nanotubes, t...

A. Ghorbanpour Arani M. Mohammadimehr Z. S. Mousavi i

In this paper, using energy method, small scale effects on the buckling analysis of a double-walled carbon nanotube (DWCNT) under external radial pressure is studied. The constitutive equations derived for a DWCNT using the nonlocal theory of elasticity which Eringen are presented for the first time. By minimizing the second variation of the total energy for a DWCNT, hence, the value of the non...

In the present paper, nonlinear radial and hoop thermoelastic stresses analysis of a disk made of FGMs material is investigated. According to this purpose, finite element method is used. In the present method, second-order one-dimensional element (with three node points) is proposed. The geometrical and stress boundary conditions are defined in the state of non-existence of external pressure an...

2016
Gaurav Rana Nikolaos Kakouros

Radial artery access has rare but significant vascular complications that can occur even in high volume centers. We present a case of a 60-year-old man with perforation of a high takeoff radial artery due to catheter manipulation. A combination of manual external pressure of the axillary artery combined with internal tamponade effect from a 45 cm hydrophilic sheath was used with no immediate or...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید