نتایج جستجو برای: Electrosurgical Equipmen

تعداد نتایج: 4110  

1998
Andrew I. Brill Joseph R. Feste Trudy L. Hamilton Antonios P. Tsarouhas Scott R. Berglund Joseph B. Petelin Paul G. Perantinides

The increase in minimally invasive procedures performed has been accompanied by an increase in the incidence of associated iatrogenic complications. A significant portion of these complications are electrosurgical in nature—stemming from surgical pilot error, improper use or maintenance of electrosurgical instrumentation, or from electrosurgical burns that occur beyond the surgeon's direct visi...

Journal: :Endoscopy 2010
J F Rey U Beilenhoff C S Neumann J M Dumonceau

Electrosurgery is used in the majority of endoscopic therapeutic procedures. An understanding of the fundamental electrosurgical principles and various settings available on electrosurgical units is essential for the safe and effective use of electrosurgery during endoscopy. The aims of these technical guidelines are to: (1) expose physical principles relevant to the understanding of electrosur...

Journal: :Surgery journal 2017
Manjunath Siddaiah-Subramanya Kor Woi Tiang Masimba Nyandowe

Diathermy is commonly used in modern-day surgery. The incidence of electrosurgical injuries related to diathermy is under reported, as it is difficult to ascertain the true impact on both patient and healthcare professionals. As junior surgical trainees, understanding of the mechanism and biophysics of the electrosurgical tools enables safer usage and contributes to improved outcome. Careful us...

2013
Manu Akula Robert R. Lipman Marek Franaszek Kamel S. Saidi Geraldine S. Cheok Vineet R. Kamat

⁎ Corresponding author. E-mail addresses: [email protected] (M. Akula), r (R.R. Lipman),[email protected] (M. Franaszek), k [email protected] (G.S. Cheok), [email protected] (V.R. Ka 1 Disclaimer: Certain commercial entities, equipment, o this document in order to describe an experimental pro Such identification is not intended to imply recommen National Institute of Standards and Technolog...

A Tavakoli Golpaygani, M M Movahedi M Reza

Introduction: Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient’s safety and management of the risks associated with the use of high and low frequency ele...

Journal: :American journal of surgery 2000
M P Wu C S Ou S L Chen E Y Yen R Rowbotham

BACKGROUND Electrosurgery is one of the most commonly used energy systems in laparoscopic surgery. Two major categories of potential complications related to electrosurgery in laparoscopy are mechanical trauma and electrothermal injury. The latter can result from unrecognized energy transfer in the operational field or, less commonly, to unnoticed stray current outside the laparoscopic field of...

Journal: :The journal of contemporary dental practice 2015
Rasoul Sahebalam Alireza Sarraf Mojtaba Abdollahi Hamid Jafarzadeh Hamidreza Rajati Shankargouda Patil

OBJECTIVES The aim of this study was to determine the probable side effects of electrosurgery in pulpectomy of deciduous teeth on succedaneous teeth in dogs. MATERIALS AND METHODS In this animal study, all maxillary and mandibular teeth at one side of five puppies' mouths were treated employing electrosurgical pulpectomy and were then compared with those of the other side treated using the co...

Journal: :Journal of gynecologic oncology 2010
Mi-Young Shin Eun-Sung Seo Suk-Joo Choi Soo-Young Oh Byoung-Gie Kim Duk-Soo Bae Jong-Hwa Kim Cheong-Rae Roh

OBJECTIVE To evaluate pregnancy outcomes after electrosurgical conization. METHODS We retrospectively analyzed the outcomes of 56 singleton pregnancies after electrosurgical conization of the uterine cervix. Of the 56 cases, 25 women underwent prophylactic cerclage with McDonald procedure (cerclage group), and 31 were managed expectantly (expectant group). Pregnancy outcomes including rate of...

Journal: :Plastic and reconstructive surgery 2009
Shang A Loh Grace A Carlson Edward I Chang Eric Huang Daniel Palanker Geoffrey C Gurtner

BACKGROUND The PEAK PlasmaBlade is a new electrosurgical device that uses pulsed radiofrequency to generate a plasma-mediated discharge along the exposed rim of an insulated blade, creating an effective cutting edge while the blade stays near body temperature. METHODS Full-thickness incisions were made on the dorsums of pigs with the PlasmaBlade, a conventional electrosurgical device, and a s...

Journal: :Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES 2005
Umut Tuncel Güzin Yeşim Ozgenel

Since the electrosurgical instruments are commonly used in a wide variety of surgical specialties, understanding of the properties of these instruments is very important to prevent the potential complications. We report the case of a patient who sustained a third-degree dermal burn caused by contact with the ground plate of the electrosurgical system. This burn healed with surgical treatment. S...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید