نتایج جستجو برای: Electroosmotic

تعداد نتایج: 802  

2001
Prashanta Dutta Ali Beskok Timothy C. Warburton

Numerical simulation results for pure electroosmotic and combined electroosmotic/pressure driven Stokes flows are presented in the cross-flow and Y-split junctions. The numerical algorithm is based on a mixed structured/unstructured spectral element formulation, which results in high-order accurate resolution of thin electric double layers with discretization flexibility for complex engineering...

2014
Daniel G. Haywood Zachary D. Harms Stephen C. Jacobson

We report the measurement of electroosmotic mobilities in nanofluidic channels with rectangular cross sections and compare our results with theory. Nanofluidic channels were milled directly into borosilicate glass between two closely spaced microchannels with a focused ion beam instrument, and the nanochannels had half-depths (h) of 27, 54, and 108 nm and the same half-width of 265 nm. We measu...

2002
Prashanta Dutta Ali Beskok Timothy C. Warburton F. F. Reuss

A spectral element algorithm is developed to analyze mixed electroosmotic=pressure driven  ows in complex two-dimensional geometries. The new algorithm exhibits spectral accuracy in resolving thin electric double layers. Mixed electroosmotic=pressure driven  ows are simulated in straight channels. Electrokinetic pumping and the means of producing large pressure gradients in microchannels are ...

2017
Pengfei Lu Xiangdong Liu Chengbin Zhang

Molecular dynamics simulation is applied to study the electroosmotic flow in rough nanochannels, with particular attention given to the fluid–solid interactions. In the simulation, the surface roughness is characterized by a fractal Cantor. The roles of roughness height and fractal dimension on nanoscale electroosmotic flow are examined and analyzed. The concentration distributions, zeta potent...

2006
Keisuke HORIUCHI Prashanta DUTTA

We analyze heat transfer characteristics of steady electroosmotic flows with an arbitrary pressure gradient in two-dimensional straight microchannels considering the effects of Joule heating in electroosmotic pumping. Both the temperature distribution and local Nusselt number are mathematically derived in this study. The thermal analysis takes into consideration of the interaction among advecti...

Journal: :Nanoscale 2012
Li-Hsien Yeh Mingkan Zhang Shizhi Qian Jyh-Ping Hsu

Nanopores have emerged as promising next-generation devices for DNA sequencing technology. The two major challenges in such devices are: (i) find an efficient way to raise the DNA capture rate prior to funnelling a nanopore, and (ii) reduce the translocation velocity inside it so that single base resolution can be attained efficiently. To achieve these, a novel soft nanopore comprising a solid-...

2016
Teng Zhou Hanlin Wang Liuyong Shi Zhenyu Liu Sang Woo Joo

Homogeneous and rapid mixing in microfluidic devices is difficult to accomplish, owing to the low Reynolds number associated with most flows in microfluidic channels. Here, an efficient electroosmotic micromixer based on a carefully designed lateral structure is demonstrated. The electroosmotic flow in this mixer with an asymmetrical structure induces enhanced disturbance in the micro channel, ...

Journal: :Analytical chemistry 1994
F A Gomez L Z Avila Y H Chu G M Whitesides

This paper describes the estimation of binding constants (Kb) between carbonic anhydrase B (CAB, EC 4.2.1.1, from bovine erythrocytes) and charged benzenesulfonamides by affinity capillary electrophoresis (ACE) under conditions in which the migration time is affected by changes in electroosmotic flow and by nonspecific interactions accompanying changes in the concentration of ligand. Comparison...

Journal: :Analytical chemistry 1993
M A Hayes I Kheterpal A G Ewing

Electroosmotic flow within capillary zone electrophoresis can be altered electronically through a mechanism modeled as surface conductance. Experimentally, a small zone of conductive silver on the outer surface of the capillary is shown to permit good control of electroosmotic flow with an applied external voltage. This control is modeled as capacitance across the capillary wall and conductance...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید