نتایج جستجو برای: ESAK

تعداد نتایج: 39  

Journal: :Radiation protection dosimetry 2016
J Nilsson Althén M Sandborg

The aim of this work was to verify the indicated maximum entrance surface air kerma (ESAK) using a GE Innova IGS 520 imaging system during cardiac interventional procedures. Gafchromic XR RV3 films were used for the patient measurements to monitor the maximum ESAK. The films were scanned and calibrated to measure maximum ESAK. Thermoluminescent dosemeters were used to measure the backscatter fa...

Journal: :Journal of radiological protection : official journal of the Society for Radiological Protection 2016
Ernest U Ekpo Suleman Bakhshi Elaine Ryan Peter Hogg Mark F McEntee

The aim of this work was to examine the peak entrance surface air kerma (peak ESAK) to the eyes during CT fluoroscopy lung biopsy, and the impact of lead glasses, exposure parameters, head rotation, and height on peak ESAK to the eyes. Two phantoms simulating the patient and radiologist were used, and 108 exposures were made using a 16-slice Toshiba Alexion CT scanner (Toshiba Medical Systems, ...

2011
F. Ibrahim

In this study radiation doses in IVU clinical examinations were measured in three public hospitals and a sample of 44 patients. In each room the machine output was measured for different peak tube voltages. Patient's data such as (age and weight) and exposure parameters (kVp) and mAs) were recorded. Entrance Surface Air Kerma (ESAK) for patients was determined by using the tube output and the p...

2003
E Kuon J Birkel M Schmitt J B Dahm

Background: Occupational head exposure to radiation in cardiologists may cause radiation induced cataracts and an increased risk of brain cancer. Objective: To determine the effectiveness of 0.5 mm lead equivalent caps, not previously used in invasive cardiology, in comparison with a 1.0 mm lead equivalent ceiling mounted lead glass screen. Design: An anthropomorphic Alderson-Rando phantom was ...

Journal: :Heart 2003
E Kuon J Birkel M Schmitt J B Dahm

BACKGROUND Occupational head exposure to radiation in cardiologists may cause radiation induced cataracts and an increased risk of brain cancer. OBJECTIVE To determine the effectiveness of 0.5 mm lead equivalent caps, not previously used in invasive cardiology, in comparison with a 1.0 mm lead equivalent ceiling mounted lead glass screen. DESIGN An anthropomorphic Alderson-Rando phantom was...

Journal: :Radiation protection dosimetry 2011
C Ubeda E Vano P Miranda F Leyton E Valenzuela C Oyarzun

The aim of this work was to investigate the differences in dose settings and image quality among 10 X-ray systems used for interventional cardiology in Chile. Entrance surface air kerma (ESAK) was measured on a phantom of 20 cm thickness of polymethyl methacrylate slabs. Image quality was evaluated using DICOM images of a test object Leeds TOR 18-FG for cine mode acquisition, through the numeri...

Journal: :Radiation protection dosimetry 2012
Aleksandra Milatović Olivera Ciraj-Bjelac Sonja Ivanović Slobodan Jovanović Vesna Spasić-Jokić

It was the aim of the study presented here to estimate for the first time patient dose levels in conventional diagnostic radiology in Montenegro. Measurements of patient dose in terms of entrance surface air kerma (ESAK) and kerma-area product (KAP) were performed on at least 10 patients for each examination type, in each of five randomly selected health institutions in Montenegro, so that a to...

2006
S Ramanaidu RB Sta Maria KH Ng J George G Kumar

PURPOSE A study of radiation dose and image quality following changes to the tube potential (kVp) in paediatric chest radiography. MATERIALS AND METHOD A total of 109 patients ranging from 1 month to 15 years were included in two phases of the study. Phase 1 investigated the range of entrance surface air kerma (ESAK) values received from patients exposed to the existing exposure factors. In t...

2013
Khalid Alzimami Abdelmoneim Sulieman Georgios Paroutoglou Spiros Potamianos Marianna Vlychou Kiki Theodorou

This study intended to optimize the radiation doses for gastroenterologists and patients during therapeutic endoscopic retrograde cholangiopancreatography (ERCP) and to compare the doses based on available data obtained by other researchers. A total of 153 patients were studied in two Gastroenterology Departments, (group A, 111; group B, 42). Thermoluminescent dosimeters (TLD) were used to meas...

2015
A. O. Masoud W.E. Muhogora P.K. Msaki

The aim of this study was to evaluate the radiation doses to patient during chest and abdomen CR examinations, and assess the related level of optimization at five referral hospitals in Tanzania. The international code of practice for dosimetry in diagnostic radiology was applied to determine the entrance surface air kerma (ESAK) to patients. The level of optimization was assessed from low-cont...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید