نتایج جستجو برای: EAF, Reactive power

تعداد نتایج: 636417  

Journal: :international journal of smart electrical engineering 2014
haidar samet mohammad amin jarrahi

electric arc furnace (eaf) is one of the largest loads in electric power systems. it is highly time varying and nonlinear. its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. on the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in eaf. to this end flexible ac transmission systems (facts) techn...

Haidar Samet, Mohammad Amin Jarrahi

Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...

2005
Jaroslav Dolezal Josef Tlusty Viktor Valouch

A linearised model of the power system with the Electrical Arc Furnace (EAF) and the Unified Power Quality Conditioner (UPQC) has been used in the frequency domain for finding an optimum control strategy of the UPQC. The analysis indicates that the most effective may be such an application of the UPQC where the parallel Active Filter (AF) compensates the whole reactive power consumed by the EAF...

2014
Jyh-Cherng Gu

This investigation develops a revisable method for estimating the estimate value of equivalent 10 Hz voltage flicker (DV10) of a DC Electric Arc Furnace (EAF). This study also discusses three 161kV DC EAFs by field measurement, with those results indicating that the estimated DV10 value is significantly smaller than the survey value. The key point is that the conventional means of estimating DV...

2007
MANUELA PANOIU CAIUS PANOIU MIHAELA OSACI IONEL MUSCALAGIU

This paper present the results obtained by simulation for the functioning regime improvement of an UHP Electric Arc Furnace. Because the nonlinearity of the electric arc the EAF functioning regime are perturbed from three causes: the current harmonics, the reactive power and the unbalanced load. In this paper there are study the possibilities of harmonics filtering and compensate the reactive p...

2006
JONG-IAN TSAI TUNG-SHENG ZHAN Rong-Ching Wu

The electrical arc furnace (EAF) load is the largest load in power systems. Since electromechanical interactions between electrical loads and turbine-generator are seldom discussed, this paper investigates the torsional vibrations in turbine-generator shafts and blades subject to real and reactive power variations from a large-scale EAF plant. The transient power fluctuation of the load is rand...

2015
Da-Bin Lee Do-Hyung Kim Jae-Young Je

Phenolic rich ethyl acetate fraction (EAF) from lotus leaves was prepared and its bioactive components, antioxidant and cytoprotective effects were investigated. EAF showed high total phenolic content and flavonoid content and contained rutin (11,331.3±4.5 mg/100 g EAF), catechin (10,853.8±5.8 mg/100 g EAF), sinapic acid (1,961.3±5.6 mg/100 g EAF), chlorogenic acid (631.9±2.3 mg/100 g EAF), syr...

2014
Deepak C. Bhonsle Ramesh B. Kelkar

Power quality is becoming a more concern of today’s power system engineer due to rapid growth of non-linear loads in distribution network. Electrical Arc Furnace (EAF) is one of the responsible causes for deteriorating power quality in the distribution network. Hence electric arc furnace model is needed to study and to analyze the power quality in the distribution network. This paper presents a...

2003
Benoit Boulet Gino Lalli Mark Ajersch

Electric arc furnaces (EAFs) are widely used in steelmaking and in smelting of nonferrous metals. The EAF is the central process of the so-called mini-mills, which produce steel mainly from scrap. Typical EAFs operate at power levels from 10MW to 100MW. The power level is directly related to production throughput, so it is important to control the EAF at the highest possible average power with ...

2009
MANUELA PĂNOIU CAIUS PĂNOIU IOAN ŞORA Manuela Pănoiu Caius Pănoiu Ioan Şora

The electric arc furnace is a three-phase load representing one of the most important generator of harmonic currents, reactive power and unbalanced conditions in electrical power systems. This paper aims to achieve a study concerning the power quality of the energy at 3-phase electric arc furnaces. There are analyzed the main qualitative indicators of the electric power: power factor, reactive ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید