نتایج جستجو برای: Dynamic Hip Screw (DHS)

تعداد نتایج: 482660  

Journal: :the archives of bone and joint surgery 0
cyril jonnes department of orthopaedics, pondicherry institute of medical sciences, pondicherry, india shishir suranigi department of orthopaedics, pondicherry institute of medical sciences, pondicherry, india syed najimudeen department of orthopaedics, pondicherry institute of medical sciences, pondicherry, india

background: intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. dynamic hip screw (dhs) is still considered the gold standard for treating intertrochanteric fractures by many. not many studies compare the dhs with proximal femoral nail (pfn), in type ii intertrochanteric ...

بهادر اعلمی هرندی, , مجید سجادی ساروی, , محمدنقی طهماسبی, ,

Cut out or extrusion of the lag screw from the superior aspect of head and neck of the femur is one of the most common and devastating complications of the surgery of the intertrochanteric fractures with DHS. The exact cause of this complications is unknown, but it seems to be related to osteopenia, inappropriate position of lag screw inside head of the femur and inability of DHS to slide insid...

باقری, فائز, نوایی‌فر, نسرین, میرزاطلوعی, فردین ,

Abstract We report a 71 year-old patient with intertrochanteric fracture who had been managed with DHS and her healed fracture complicated by a subcapital femoral neck fracture. A subcapital femoral neck fracture complicating a healed intertrochanteric fracture is rare but catastrophic event. Such cases are managed in a hetereogenous manner, i.e. there exists a mixture of cases tr...

2016
Hong Man Cho Kyujung Lee

PURPOSE We aimed to evaluate and compare the clinical and functional outcomes of dynamic hip screw (DHS) and proximal femoral nail antirotation (PFNA) treatment of AO type 1 intertrochanteric fractures in elderly patients. MATERIALS AND METHODS We retrospectively reviewed 194 consecutive patients with type A1 intertrochanteric femoral fractures who were treated with DHS (n=113) or PFNA (n=81)...

Journal: :مجله پزشکی ارومیه 0
نسرین نوایی فر nasrin navaeifar orthopedic surgery department, imam khomeini hospital, urmia university of medical sciences, urmia, iranارومیه، دانشگاه علوم پزشکی ارومیه، مرکز آموزشی و درمانی امام خمینی (ره)، تلفن: 09111358426سازمان اصلی تایید شده: دانشگاه علوم پزشکی ارومیه (urmia university of medical sciences) فردین میرزاطلوعی fardin mirzatolouei professor,orthopedic surgery department, faculty of medicine, imam khomeini hospital, urmia university of medical sciences, urmia, iranاستاد ارتوپدی، دانشگاه علوم پزشکی ارومیه، ارومیه، ایرانسازمان اصلی تایید شده: دانشگاه علوم پزشکی ارومیه (urmia university of medical sciences) فائز باقری faez bagheri orthopedic surgery department, faculty of medicine, imam khomeini hospital, urmia university of medical sciences, urmia, iranدانشگاه علوم پزشکی ارومیه، ارومیه، ایرانسازمان اصلی تایید شده: دانشگاه علوم پزشکی ارومیه (urmia university of medical sciences)

abstract we report a 71 year-old patient with intertrochanteric fracture who had been managed with dhs and her healed fracture complicated by a subcapital femoral neck fracture. a subcapital femoral neck fracture complicating a healed intertrochanteric fracture is rare but catastrophic event. such cases are managed in a hetereogenous manner, i.e. there exists a mixture of cases treated by eithe...

آقامیرسلیم, محمدرضا, سربی, رضا, طوافی, محمدرضا, مهرپور, سعیدرضا,

Background: Comminuted subtrochanteric fractures have been a challenge for orthopedic surgeons in terms of appropriate reduction and stable fixation. Numerous methods have been used for the fixation of comminuted subtrochanteric fractures among which some are accompanied with technical difficulties and complications of their own. Regarding the results of previous studies, we decided to evaluate...

2012
Supakit Rooppakhun Nattapon Chantarapanich Bancha Chernchujit Banchong Mahaisavariya Sedthawatt Sucharitpwatskul Kriskrai Sitthiseripratip

This study aimed to present the mechanical performance evaluation of the dynamic hip screw (DHS) for trochanteric fracture by means of finite element method. The analyses were performed based on stainless steel and titanium implant material definitions at various stages of bone healing and including implant removal. The assessment of the mechanical performance used two parameters, von Mises str...

2015
John Dabis Hani B. Abdul-Jabar Hosam Dabis

Dynamic hip screw fixation is a common orthopaedic procedure and to date, still can cause difficulties to the senior trauma surgeon. We present a case where an extra-capsular fracture of the proximal femur was managed with a dynamic hip screw (DHS) fixation. She proceeded to the operating theatre, where the fracture was stabilized with a 75-mm DHS and short-barrelled plate. The implant position...

2018
Chunlei Zhang Bin Zhang Qirong Dong Dawei Ge

Background: The aim of this article is to introduce a novel technique of limited dynamic hip screw (LDHS) in the treatment of intertrochanteric fractures and to evaluate its biomechanical effects. Material/Methods: Based on the principle of providing both dynamic and static pressure to stabilize the fracture, we improved the dynamic hip screw (DHS) and designed the LDHS. Six fresh cadavers were...

Journal: :trauma monthly 0
mohsen mardani-kivi orthopedic department of pursina hospital, guilan university of medical science, rasht, ir iran ahmadreza mirbolook orthopedic department of pursina hospital, guilan university of medical science, rasht, ir iran; orthopedic department of pursina hospital, guilan university of medical sciences, rasht, ir iran. tel.: +98-9112310025, fax: +98- 1313221572 sina khajeh jahromi student research committee, guilan university of medical sciences, rasht, ir iran melina rouhi rad student research committee, guilan university of medical sciences, rasht, ir iran

conclusions despite the complications of fixation with the dhs device, it remains the most successful for treatment of intertrochanteric fractures. background according to the existing literature, the dynamic hip screw (dhs) is the preferred standard for the treatment of intertrochanteric fractures. however, some surgeons use other devices such as the locking compression plate (lcp). objectives...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید