نتایج جستجو برای: Dosimetry Calculation

تعداد نتایج: 109521  

Journal: :iranian journal of radiation research 0
n. babaei bidmeshki department of energy engineering, sharif university of technology, p.o. box 1485893169, tehran, iran m. sohrabpour department of energy engineering, sharif university of technology, p.o. box 1485893169, tehran, iran s.r. mahdavi department of medical physics, faculty of medicine, tehran university of medical sciences p.o. box 1449614525, tehran, iran

background: the purpose of this project was to derive the brachytherapy dosimetric functions described by american association of physicists in medicine (aapm) tg-43 u1 based on high dose rate 192i sources. materials and methods: the method utilized included both simulation of the designed polymethyl methacrylate (pmma) phantom using the monte carlo of mcnp4c and benchmarking of the simulation ...

Journal: :journal of medical signals and sensors 0
daryoush shahbazi-gahrouei saba ayat

introduction: radioiodine therapy is an effective method for treating thyroid cancer carcinoma, but it has some affects on normal tissues, hence dosimetry of vital organs are important to weigh the risks and benefits of this method. the aim of this study is to measure the absorbed doses of important organs by mcnp (monte carlo n particle) simulation and comparing the results of different method...

2013
F Nordström

In this study, a 4D dosimetry concept was developed. This concept included a method for calculation of 3D reference absorbed dose matrices at every control point of the delivery using a clinical treatment planning system (TPS). Further, the gamma evaluation method was extended to incorporate the 4 dimension of the TPS calculated dose distributions. The applications of the 4D dosimetry concept o...

2014
Kenichi Tanaka Kunihiko Tateoka Osamu Asanuma Ken-ichi Kamo Kaori Sato Hiromitsu Takeda Masaru Takagi Masato Hareyama Jun Takada

The post-implantation dosimetry for brachytherapy using Monte Carlo calculation by EGS5 code combined with the source strength regression was investigated with respect to its validity. In this method, the source strength for the EGS5 calculation was adjusted with the regression, so that the calculation would reproduce the dose monitored with the glass rod dosimeters (GRDs) on a water phantom. T...

قرائتی, حسین, اصفهانی, مهبد, اله‌وردی, محمود, سمیعی, فرهاد, شرفی, علی‌اکبر,

In vivo dosimetry seems an appropriate method for quality assurance in radiotherapy with CO-60, which can be considered as a routine program in radiotherapy centers. In this study, entrance and exit dose in tangential fields were measured in phantom for 30 breast cancer patients by using TLD in radiotherapy section of Imam Khomeini Hospital. TLD crystals were calibrated against SSDL (Secondary...

Journal: :Journal of physics. Conference series 2009
Hs Sakhalkar D Sterling J Adamovics G Ibbott M Oldham

An urgent requirement for 3D dosimetry has been recognized because of high failure rate (~25%) in RPC credentialing, which relies on point and 2D dose measurements. Comprehensive 3D dosimetry is likely to resolve more errors and improve IMRT quality assurance. This work presents an investigation of the feasibility of PRESAGE/optical-CT 3D dosimetry in the Radiologic Physics Center (RPC) IMRT H&...

2005
H. Palmans R. Thomas D. Shipley P. Sharpe S. Duane A. DuSautoy

A Strategic Research project was performed at NPL with the aim of investigating issues and potential improvements for light-ion dosimetry. The objectives of the project were: a literature survey, testing a number of dosimeters in the proton therapy beam of Clatterbridge Centre of Oncology (CCO), measurement of dose distributions, measurement and calculation of detector perturbations, explore th...

2010
Reichmann

Dosimetry is the process of calculating the effective radioactive dose that is applied to tumors and organs respectively as a patient undergoes a peptide receptor radionuclide therapy. This work presents the novel application software ‘DoSE8’ that was developed from our group and that incorporates all necessary image processing steps (registration and segmentation) and data handling for (partly...

2012
Daniel W. Bailey Lalith Kumaraswamy Mohammad Bakhtiari Harish K. Malhotra Matthew B. Podgorsak

This study compares the EPID dosimetry algorithms of two commercial systems for pretreatment QA, and analyzes dosimetric measurements made with each system alongside the results obtained with a standard diode array. 126 IMRT fields are examined with both EPID dosimetry systems (EPIDose by Sun Nuclear Corporation, Melbourne FL, and Portal Dosimetry by Varian Medical Systems, Palo Alto CA) and th...

2001
Mehrdad Sarfaraz Cedric Yu D. J. Chen Leon Der

We have constructed a computer controlled translational couch to administer total body irradiation reproducibly and safely. The system has replaced the previous stationary anterior-posterior technique in our institution and 30 plus patients have been treated with it so far. In this technique, patients comfortably lie on a couch in supine and prone positions and are transported slowly through a ...

نمودار تعداد نتایج جستجو در هر سال