نتایج جستجو برای: Dosimetric characteristics Monte Carlo simulation

تعداد نتایج: 1231401  

آقامیری, سید محمود رضا, باغانی, حمیدرضا, حیدرلو, نعمت‌الله, مهدوی, سید ربیع,

Intraoperative electron radiotherapy is one of the radiotherapy methods that delivers a high single fraction of radiation dose to the patient in one session during the surgery. Beam shaper applicator is one of the applicators that is recently employed with this radiotherapy method. This applicator has a considerable application in treatment of large tumors. In this study, the dosimetric charact...

Journal: :iranian journal of radiation research 0
m.b. tavakoli department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran d. shahbazi-gahrouei department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran m. hosseinpour department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran

background: for an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. the usual method to determine these factors is thermo luminescent dosimeter (tld) dosimetry. nowadays, another more accurate method is known to be the monte carlo ...

D. Shahbazi-Gahrouei, M. Hosseinpour, M.B. Tavakoli,

Background: For an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. The usual method to determine these factors is thermo luminescent dosimeter (TLD) dosimetry. Nowadays, another more accurate method is known to be the Monte Carlo ...

Journal: :journal of biomedical physics and engineering 0
m robatjazi tehran university of medical sciences k tanha bushehr university of medical sciences s r mahdavi iran university of medical sciences h r baghani shahid beheshti university h r mirzaei shahid beheshti university of medical sciences m mousavi tehran university of medical sciences

background: one of the main problems of dedicated iort accelerators is to determine dosimetric characteristics of the electron beams. monte carlo simulation of iort accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry. materials and methods: liac accelerator head was modeled using the beamnrcmonte carlo simulation system. phase-space files were generated a...

Journal: :iranian journal of radiation research 0
m. zehtabian radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran r. faghihi radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran s. sina radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran

background: iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. dosimetric parameters of brachytherapy sources should be determined according to aapm tg-43u1 recommendations before clinical use. monte carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. materials and methods: dosimetric parameters (dos...

Ali Reza Kamali-Asl Hamid Reza Hemmati Mohammad Reza Javanshir Nematollah Heidarloo, Vahid Lohrabian

Introduction: 192Ir is one of the important sources frequently used in brachytherapy. Up to now, a lot of commercial models of this source have been made which Ir-192 has been recently added to them. The aim of the present study is to determine the dosimetric parameters of this new source model based on the recommendations of TG-43(U1) protocol using Monte Carlo simulation tech...

Journal: :iranian journal of radiation research 0
a.s. meigooni university of kentucky medical center, department of radiation medicine, lexington, kentucky, usa u. malik h. zhang s.a. dini n. j. meigooni k. komanduri

background: an effective method for management of large and bulky malignant tumors. this treatment modality is also known as specially fractionated radiation therapy (sfrt). in this treatment technique a grid block converted the open radiation field into a series of pencil beams. dosimetric characteristics of an external beam grid radiation field have been investigated using experimental and mo...

A.S. Meigooni, H. Zhang, K. Komanduri, M. Mohiuddin, N. J. Meigooni, S.A. Dini, U. Malik,

Background: An effective method for management of large and bulky malignant tumors. This treatment modality is also known as Specially Fractionated Radiation Therapy (SFRT). In this treatment technique a grid block converted the open radiation field into a series of pencil beams. Dosimetric characteristics of an external beam grid radiation field have been investigated using experimental and Mo...

M. Zehtabian, R. Faghihi, S. Sina,

Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...

E Akbari, H R Baghani H R Mirzaei K Tanha, M Mousavi, M Robatjazi, N Nafissi, S R Mahdavi,

Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید