Journal: :iranian journal of radiology 0
lida gholamkar department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran ali asghar mowlavi physics department, hakim sabzevari university, sabzevar, iran; international center for theoretical physics (ictp), associate federation scheme, medical physics field, trieste, italy; physics department, hakim sabzevari university, sabzevar, iran. tel: +98-5144012521 mahdi sadeghi radiation application research school, nuclear science and technology research institute, tehran, iran mitra athari department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

conclusion by comparing the results, we saw that w/rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with w/ag and rh/al. moreover, breast thickness and g value have significant effects on mgd. objectives the aim of this study was to determine the average absorbed dose of x-ray radiation in the glandular tissue of the...

Journal: :iranian journal of nuclear medicine 2007
faraz kalantari hossein rajabi nahid yaghoobi ahmad bitarafan rajabi kourosh gorji

introduction: poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. scattered photons are the main cause of degrading the contrast and resolution in spect imaging that result in error in quantification. thallium decay is very complicated and photons ar...

Journal: :asia oceania journal of nuclear medicine and biology 0
mana akamatsu department of medical technology, kyushu university hospital, japan yasuo yamashita department of medical technology, kyushu university hospital, japan go akamatsu institute of biomedical research and innovation, japan yuji tsutsui department of medical technology, kyushu university hospital, japan nobuyoshi ohya department of medical technology, kyushu university hospital, japan yasuhiko nakamura department of medical technology, kyushu university hospital, japan

objective: the aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123i brain spect obtained by the hybrid spect/ct device. methods: we used the 3-dimensional (3d) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. it was filled with 123i solution (20...

Journal: :iranian journal of medical physics 0
somayeh gholami m.sc., nuclear engineering dept., shahid beheshti university, tehran, iran alireza kamali asl assistant professor, nuclear engineering dept., shahid beheshti university, tehran, iran seyed mahmood aghamiri assistant professor, nuclear engineering dept., shahid beheshti university, tehran, iran mahmood allahverdi assistant professor, medical physics dept., tehran university, tehran, iran

introduction: gamma knife is an instrument specially designed for treating brain disorders. in gamma knife, there are 201 narrow beams of cobalt-60 sources that intersect at an isocenter point to treat brain tumors. the tumor is placed at the isocenter and is treated by the emitted gamma rays. therefore, there is a high dose at this point and a low dose is delivered to the normal tissue surroun...

2012
Sung Eun Song Bo Kyoung Seo An Yie Bon Kyung Ku Hee-Young Kim Kyu Ran Cho Hwan Hoon Chung Seung Hwa Lee Kyu-Won Hwang

OBJECTIVE To compare between the American College of Radiology (ACR) accreditation phantom and digital mammography accreditation phantom in assessing the image quality in full-field digital mammography (FFDM). MATERIALS AND METHODS In each week throughout the 42-week study, we obtained phantom images using both the ACR accreditation phantom and the digital mammography accreditation phantom, a...

Journal: :Medical physics 2012
J Deng

PURPOSE To develop a realistic yet flexible 4D digital phantom based on patient anatomy for dynamic estimation of organ doses due to external ionizing radiation. METHODS In this work, we propose to build a 4D digital phantom based on patient CT anatomy and time-tagged CT information. A regional 4D-CT is first acquired on the patient around lesion with a RPM system. By binning CT information a...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2009
Chieko Nagashima Nachiko Uchiyama Noriyuki Moriyama Mio Nagata Hiroyuki Kobayashi Katsuhiro Sankoda Shigeru Saotome Masahiro Tagi Tetsurou Kusunoki

Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The dig...

Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...

2012
Claudia C. Brunner Raymond J. Acciavatti Predrag R. Bakic Andrew D. A. Maidment Mark B. Williams Richard Kaczmarek Kish Chakrabarti

We investigated the appropriateness of four different mammography phantoms for image quality evaluation in Digital Breast Tomosynthesis (DBT). We tested the CIRS BR3D phantom, the ACR Prototype FFDM Accreditation Phantom, the Penn anthropomorphic breast phantom and the Quart mam/digi EPQC phantom. This work discusses the advantages and shortcomings of each phantom and concludes that none of the...

2001
Eugene Mah Ehsan Samei Donald J. Peck

RATIONALE AND OBJECTIVES To examine the effectiveness and suitability of a quality control (QC) phantom for a routine QC program in digital radiography. MATERIALS AND METHODS The chest phantom consists of copper and aluminum cutouts arranged to resemble the appearance of a chest. Performance of the digital radiography (DR) system is evaluated using high and low contrast resolution objects pla...