introduction: nowadays new radiochromic films have an essential role in radiotherapy dosimetry. properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. material and methods: in this study, electron-beam dose distributions in homogenous and heterogeneous pha...
Intraoperative electron radiotherapy is one of the radiotherapy methods that delivers a high single fraction of radiation dose to the patient in one session during the surgery. Beam shaper applicator is one of the applicators that is recently employed with this radiotherapy method. This applicator has a considerable application in treatment of large tumors. In this study, the dosimetric charact...
background: understanding of the incident electron energy and angular distributions from clinical electron accelerators (linacs) is important for dosimetry and treatment planning. the most important goals of this study were to evaluate the energy fluence and angular distributions of electron beams from a neptun 10pc linac using the monte carlo (mc) code. materials and methods: the linac electro...
Background and purpose: Beam shaper is a type of applicator used in conjunction with the intraoperative electron radiotherapy. This study aimed at quantitative evaluation of the photon contamination of this applicator using Monte Carlo simulation. Materials and methods: In this experimental study, at first the head of LIAC accelerator was simulated along with the beam shaper applicator using...
The specific design of the mobile dedicated intraoperative radiotherapy (IORT) accelerators and different electron beam collimation system can change the dosimetric characteristics of electron beam with respect to the conventional accelerators. The aim of this study is to measure and compare the dosimetric characteristics of electron beam produced by intraoperative and conventional radiotherapy...
The spatial coherence properties of a monochromatic component of synchrotron radiation from an insertion device in the Fraunhofer limit are analyzed in the general case when the coherence distance is comparable with the beam width, expressing them by simple products and convolutions of Fourier transforms and autocorrelations on the single-electron field amplitude and the electron-beam position ...
introduction magnetic fields are capable of altering the trajectory of electron beams andcan be used in radiation therapy.theaim of this study was to produce regions with dose enhancement and reduction in the medium. materials and methods the ndfeb permanent magnets were arranged on the electron applicator in several configurations. then, after the passage of the electron beams (9 and 15 mev va...
background: field matching problems in abutting electron fields can be managed by using spoilers. objective: the aim of this study was to design a monte carlo framework for the assessment of spoiler application in abutting electron fields. methods: a siemens primus treatment head was simulated for a 5 mev electron beam using beamnrc and dosxyznrc, egsnrc user codes. validation of beam model was...