نتایج جستجو برای: Centrifugal Pump

تعداد نتایج: 70035  

Journal: :journal of mechanical research and application 2012
egils dzelzitis deniss pilscikovs

the goal of this research is the derivation of method for evaluation of efficiency improvement potential for district heating systems with focus on variable speed centrifugal pump. the effectiveness of the usage of the proportional pressure control is compared with the constant pressure control. this is why, energy calculation analyses have been realized for variable speed centrifugal pumps, an...

Now a day centrifugal pumps are vital components of industries. Certainly, one of the most important specifications of centrifugal pumps are the performance curves. In the present work, performance curves of a centrifugal pumps are obtained by Computational fluid dynamics (CFD) and as an outcome, CFD results compare by practical curves. At the first step impeller and volute are designed with tw...

2009
Khin Cho Mya Mya Khaing Khin Maung Aye

This paper deals with the design and performance analysis of centrifugal pump. In this paper, centrifugal pump is analyzed by using a single-stage end suction centrifugal pump. Two main components of a centrifugal pump are the impeller and the casing. The impeller is a rotating component and the casing is a stationary component. In centrifugal pump, water enters axially through the impeller eye...

2013
Myung Jin Kim

In this study, to accurately predict cavitation of a centrifugal pump, numerical analysis was compared with experimental results modeled on a small industrial centrifugal pump. In this study, numerical analysis was compared with experimental results modeled on a small industrial centrifugal pump for reliable prediction on cavitation of a centrifugal pump. To improve validity of the numerical an...

In this paper, a simulation-based method is proposed for optimal placement of vibration sensors for the purpose of fault detection in a centrifugal pump. The centrifugal pump is modeled to investigate the effect of vane tip fault on fluid flow patterns numerically. Pressure pulsations are investigated at different locations at the inner surface of the pump before and after the presence of the f...

Journal: :The journal of extra-corporeal technology 1996
J P Montoya S I Merz R H Bartlett

A prototype of a non-occlusive pressure-regulated blood pump (M-pump) was evaluated in-vitro for safety in a comparative study with the roller and centrifugal pumps. The M-pump consists of collapsible tubing of unique design wrapped under tension around a rotor without a stator. The prototype M-pumps were tested in vitro to evaluate performance with respect to flow/ pressure characteristics, he...

Journal: :international journal of advanced design and manufacturing technology 0
anant jitendrakumar sheth gujarat technological university, gujarat, india

with the prolonged use of domestic centrifugal pump, due to erosion, corrosion and an unbalance the sever vibration of the pump are resulted. an erratic sound coming out of pump makes the user uncomfortable. here, tuned vibration absorber (tva) is used as a vibration controlling device. it is designed to reduce the rms velocity below 20% of the circumferential speed, at which the impeller is ba...

2015
Taimoor Asim Rakesh Mishra

Centrifugal pumps are an integral part of plants used in process industries. The flow structure within a centrifugal pump is very complex due to the interaction between the rotating impeller and the geometric features around it. In the present study, numerical investigations on a centrifugal pump have been carried out using a Computational Fluid Dynamics (CFD) based solver. This study employs f...

Journal: :The journal of extra-corporeal technology 2003
David Jegger Hendrik T Tevaearai Xavier M Mueller Judith Horisberger Ludwig K von Segesser

Vacuum-assist venous drainage (VAVD) can increase venous blood return during cardiopulmonary bypass (CPB) procedures. However, the negative pressure created in the closed cardiotomy reservoir can be transmitted to the oxygenator if a nonocclusive or centrifugal arterial pump is used, resulting in bubble transgression (BT) from the gas to blood compartment of the oxygenator. We analyzed the vacu...

Journal: :journal of petroleum science and technology 0
hiep vo phan new mexico institute of mining and technology tan nguyen new mexico institute of mining and technology eissa al-safran kuwait university arild saasen det norske oljeselskap asa olav-magnar nes det norske oljeselskap asa

this paper presents the effect of high viscosity oil and two-phase foamy-oil flow on the performance of a single stage centrifugal pump. as a part of this, the applicability of a pipe viscometer to determine the foamy oil viscosity is investigated. unlike previous studies, a sealed fluid tank is used in a closed flow loop to allow conditioning the two-phase mixture to create foamy-oil. furtherm...