نتایج جستجو برای: Cardiac Output Estimation

تعداد نتایج: 698528  

Journal: :journal of biomedical physics and engineering 0
a vakily h parsaei m m movahhedi m a sahmeddini

background: cardiac output (co) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. co is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. hence, measuring co has always been a matter of interest to researchers and clinicians. sev...

Journal: :Journal of the Royal Army Medical Corps 1990

Journal: :the journal of tehran university heart center 0
hassan teimouri shahid madani hospital, lorestan university of medical sciences, lorestan, iran. feridoun sabzi imam ali hospital, kermanshah university of medical sciences, kermanshah, iran. babak nasiri shahid madani hospital, lorestan university of medical sciences, lorestan, iran.

right ventricular failure due to right coronary artery disease, right ventricular hypertrophy, stunning, abnormal septal motion, myocardial infarction, or non-homogeneous distribution of cardioplegia is an uncommon but serious complication of open heart surgery. we report a patient with severe right ventricular hypertrophy secondary to severe mitral valve stenosis and another patient with detac...

2006
Oscar Luis Paredes Junya Shite

everal studies suggest the importance of cardiac power output calculation, which is derived from cardiac output (CO) and mean blood pressure, to predict the prognosis in heart failure patients not only in hospital but also in the outpatient setting.1–3 CO measured by the thermodilution method with a Swan-Ganz catheter placed in the pulmonary artery has become one of the most widely accepted and...

2013
Hetal H. Mehta Brian G. Choi Reza Sanai Raman S. Dusaj Amr Mohsen Chunlei Liang Jannet F. Lewis Robert K. Zeman

Background: Cardiac output can be estimated during retrospectively gated CT coronary angiography by anatomically determining left ventricular volumes; prospective triggering to minimize radiation precludes this methodology. We propose an alternative method for cardiac output estimation based on preclinical models suggesting that cardiac output may be inversely related to contrast washout from t...

2010
M. STORK J. NOVAK

Cardiac output (CO) is one of the most important hemodynamic signals to measure in patients with compromised cardiovascular performance. A variety of cardiac output estimators have been developed over the past hundred years. The estimator evaluated in this paper is based on oxygen uptake measured during exercise to estimate cardiac output and use heart rate (HR) to obtain also stroke volume (SV...

Journal: :برنامه ریزی و بودجه 0
فیروزه عزیزی firoozeh azizi دانشگاه تربیت مدرس

one of the most important economic factors is potential output. in macroeconomic models and structural studies, the estimation of potential output is necessary for projections and analyzing policy performances. there exist several methods for estimating potential output. meanwhile, its estimation is a difficult and complicated matter. empirical studies and researches show that using various tec...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید