نتایج جستجو برای: Cantilever

تعداد نتایج: 5052  

Journal: :international journal of nano dimension 0
m. abbasi school of mechanical engineering, shahrood branch, islamic azad university, shahrood, iran.

the resonant frequency and sensitivity of an atomic force microscope (afm) cantilever with assembled cantilever probe (acp) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. the proposed acp comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the afm capable of topography at sidew...

The resonant frequency and sensitivity of an atomic force microscope (AFM) cantilever with assembled cantilever probe (ACP) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. The proposed ACP comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the AFM capable of topography at sidew...

Journal: :international journal of advanced design and manufacturing technology 0
rouhollah hosseini phd at university of tehran young researchers and elite club, south tehran branch mohsen hamedi university of tehran

abstract: the main aim of the vibration energy harvesters is to locally power autonomous devices such as wireless sensors. generally, power levels are low and the environmental benefit of the technology is to replace batteries rather than saving energy per se. piezoelectric vibrational energy harvesters are usually inertial mass based devices, where a cantilever beam with a piezoelectric outer ...

1996
Akihiro Torii Minoru Sasaki Kazuhiro Hane Shigeru Okuma

Cantilevers fabricated by means of micromachining techniques are usually used for atomic force microscopy. In this paper, the spring constant of an atomic force microscope (AFM) cantilever is determined by using a large-scale cantilever. Since the spring constant of the large-scale cantilever is calibrated accurately, the spring constant of the AFM cantilever is determined precisely by measurin...

The resonant frequency and sensitivity of an atomic force microscope (AFM) cantilever with assembled cantilever probe (ACP) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. The proposed ACP comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the AFM capable of topography at sidew...

2008
Ji-Hyun Park Sung-Hun Kim Jung-Suk Han

Although dental implants have been successfully used for the rehabilitation of fully edentulous and partially edentulous patients, patient’s various conditions constrict the application of implant, or make dental treatment using dental implants very complex and difficult. Implantsupported cantilever prostheses represent that conditions. Becker and Kaiser insisted that alignment problems, extens...

2017
Glen Innes

This paper presents a case study of geotechnical design of bridge foundations and approaches in hilly granite formation in northern New South Wales of Australia. Firstly, the geological formation and existing cut slope conditions which have high risks of rock fall will be described. The bridge has three spans to be constructed using balanced cantilever method with a middle span of 150 m. After ...

2017

Micromechanical cantilevers show great potential as highly sensitive biochemical sensors. Cantilever-based sensing involves the transduction of a biomolecular interaction to a measurable mechanical change in the cantilever resulting from induced surface stresses added mass. In surface stress sensing applications, one side of the cantilever beam is rendered sensitive to a specific target molecul...

2015

S.Z. cantilevers are made using a simple one-mask fabrication process with.characterization of a cantilever-type MEMS chemical sensor for detection of chemicals. MEMS has been with the advancement of cantilever-type sensors.sensor. The mechanical structure is a cantilever, having its own resonant frequency. MEMS cantilevers can be as thin as a few nanometers with lengths.Cantilever-based Sensor...

2012
P. Sangeetha

Micromechanical cantilevers show great potential as highly sensitive biochemical sensors. Cantilever-based sensing involves the transduction of a biomolecular interaction to a measurable mechanical change in the cantilever resulting from induced surface stresses added mass. In surface stress sensing applications, one side of the cantilever beam is rendered sensitive to a specific target molecul...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید