نتایج جستجو برای: Breast Dose

تعداد نتایج: 547630  

Journal: :iranian journal of medical physics 0
somayeh nourollahi m.sc.in medical physics, faculty of medicine, tehran university of medical sciences, tehran, iran mahmoud allahverdi associate professor, medical physics dept., faculty of medicine, tehran university of medical sciences, tehran, iran mahbod esfahani m.sc.in medical physics, radiotherapy dept., cancer institute, tehran university of medical sciences, tehran, iran mehdi aghili assistant professor, radiotherapy dept., cancer institute, tehran university of medical sciences, tehran, iran vahid changizi assistant professor, radiology technology dept., faculty of allied medical sciences, tehran university of medical sciences, tehran, iran

introduction: the complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (ptv) result in perturbations in dose distribution. this problem can result in overdosage or underdosage in the match region of the three treatment fields. the purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...

Journal: :journal of biomedical physics and engineering 0
b farhood tehran university of medical science m t bahreyni toossi medical physics department, faculty of medicine, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه تهران (tehran university) h vosoughi medical physics department, faculty of medicine, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) s khademi medical physics research center,mashhad university of medical sciences,mashhad,iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) c knaup comprehensive cancer centers of nevada, las vegas, nevada, usaسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences)

background: breast cancer is the most frequently diagnosed cancer and the leading global cause of cancer death among women worldwide. radiotherapy plays a significant role in treatment of breast cancer and reduces locoregional recurrence and eventually improves survival. the treatment fields applied for breast cancer treatment include: tangential, axillary, supraclavicular and internal mammary ...

Journal: :iranian journal of radiation research 0
m. akram department of physics, the islamia university of bahawalpur pakistan k. iqbal department of physics, the islamia university of bahawalpur pakistan m. isa department of physics, the islamia university of bahawalpur pakistan m. afzal department of physics, the islamia university of bahawalpur pakistan s.a. buzdar department of physics, the islamia university of bahawalpur pakistan

background: it was intended to investigate the effect of physical wedge (pw) and enhanced dynamic wedges (edw) on contralateral breast dose during primary breast irradiation in radiotherapy treatment, using high energy photon beams. materials and methods: the varian’s clinac dual mode linear accelerator model 2100 c/d and siemen’s primus accelerators were used for radiation doses with 6 mv and ...

Journal: :iranian journal of radiology 0
lida gholamkar department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran ali asghar mowlavi physics department, hakim sabzevari university, sabzevar, iran; international center for theoretical physics (ictp), associate federation scheme, medical physics field, trieste, italy; physics department, hakim sabzevari university, sabzevar, iran. tel: +98-5144012521 mahdi sadeghi radiation application research school, nuclear science and technology research institute, tehran, iran mitra athari department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

conclusion by comparing the results, we saw that w/rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with w/ag and rh/al. moreover, breast thickness and g value have significant effects on mgd. objectives the aim of this study was to determine the average absorbed dose of x-ray radiation in the glandular tissue of the...

شرفی, علی‌اکبر, نیکوفر, علیرضا, مهدوی, ربیع , چگینی, ناهید ,

    Contralateral breast dose from primary breast irradiation has been implicated in the risk of second breast malignancies. In the radiotherapy departments of Iran, based on oncologist’s and physicist’s viewpoint, a special technique and set-up may be used for treatment of chest wall in mastectomized patient. The present study compared three different breast treatment techniques and set-up use...

Journal: :iranian journal of radiation research 0
a.d. esmaeeli department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran m. pouladian department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran a.s. monfared department of medical physics, babol university of medical sciences, babol, iran s.r. mahdavi department of medical physics, tehran university of medical sciences, tehran, iran d. moslemi department of radiation oncology, babol university of medical sciences, babol, iran

background: to reduce the dose to normal tissues surrounding the treated breast, a uniform magnetic field was used within a humanoid phantom in breast radiotherapy. materials and methods: monte carlo simulations were performed with geant4, irradiating humanoid phantoms in a magnetic field. to reconstruct phantoms, computed tomography (ct) data slices of four patients were used for the monte car...

F. Bouzarjomehri, M. Rezaie Yazdi,

Background: The radiation dose received by contralateral breast (CLB) is one of the concerns of breast radiotherapy, because it may lead to the induction of secondary breast cancer. The aim of this study was to evaluate the CLB surface dose in the breast treatment in Yazd radiotherapy center. Materials and Methods: The surface dose of CLB was measured using TLD dosimetry in 50 cancer breast pat...

Journal: :iranian journal of medical physics 0
hossein salehi yazdi m.sc. student of medical radiation engineering , nuclear engineering and physics dept., amirkabir university of technology, tehran, iran mojtaba shamsaei assistant professor, nuclear engineering and physics dept., amirkabir university of technology, tehran, iran hamid reza shabani m.sc. student of medical physics, medical physics dept., tehran university of medical sciences, tehran, iran ramin jaberi radiotherapy physicist, cancer institute, imam khomeini hospital, tehran, iran saeed setayeshi associate professor, nuclear engineering and physics dept., amirkabir university of technology, tehran, iran

introduction: this study investigates to what extent the computed dose received by lung tissue in a commercially available treatment planning system (tps) for 192ir high-dose-rate breast brachytherapy is accurate in view of tissue inhomogeneities and presence of ribs. materials and methods: a ct scan of the breast was used to construct a patient-equivalent phantom in the clinical treatment plan...

Alireza Shirazi Hosseini Dokht Fatemeh Mahdavi Mahdi Sadeghi,

Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...

M Papie R Faghihi S Sina

Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید