نتایج جستجو برای: Anti-insulation

تعداد نتایج: 372040  

In this paper, the thermal performance of four common insulators in two internal and external insulation systems is investigated for the ASHRAE setpoint range by applying detailed numerical simulation and Anti-Insulation phenomenon. Anti-Insulation phenomenon and consequent extra load on the HVAC system can occur following the thermal insulation of a building if proper temperature setpoint is n...

2017
Yasin M. Idris Masayuki Mae

The data in this article are the simulation results of 1248 cases that were carried out to detect anti-insulation behaviour in the article titled "Anti-insulation mitigation by altering the envelope layers' configuration" (Idris and Mae, 2017) [1]. These cases are generated by a matrix of 13 climates, 6 envelope layer configurations, 4 occupancy profiles and 4 levels of insulation thickness. Th...

Journal: :Applied human science : journal of physiological anthropology 1999
K Kuklane I Holmér G Giesbrecht

Moisture inside the footwear can considerably affect the thermal insulation. In this study with a thermal foot model there was simulated three sweat rates (3, 5 and 10 g/h). Five types of footwear with various insulation levels (dry insulation from 0.19 to 0.50 m2. K/W) were tested. The footwear insulation reduction was calculated for 1.5 hour period. The reduction in insulation was related to ...

2014
Abhishek Prasad Qing-Shan Xue Robert Dieme Viswanath Sankar Roxanne C. Mayrand Toshikazu Nishida Wolfgang J. Streit Justin C. Sanchez

Pt/Ir electrodes have been extensively used in neurophysiology research in recent years as they provide a more inert recording surface as compared to tungsten or stainless steel. While floating microelectrode arrays (FMA) consisting of Pt/Ir electrodes are an option for neuroprosthetic applications, long-term in vivo functional performance characterization of these FMAs is lacking. In this stud...

2004
Mark E. Mankowski J. Kenneth Grace

The tunneling ability of the Formosan subterranean termite Coptotermes formosanus Shiraki through a cellulose insulation material containing11.1% boric acid was tested in choice and nochoice bioassays. We examined tunneling behavior and mortality of termites exposed to treated and untreated insulation material in miniature simulated wall voids. In a choice test termites tunneled through untreat...

2014
Sihyun Park Bo-Hye Choi Jae-Han Lim

Buildings account for a significant portion of a nation’s total energy consumption. To meet the global demand for greater energy efficiency, many countries are drastically strengthening insulation regulations for buildings. Thus, dramatically thicker wall insulation may be required, which can adversely affect the value of a building by reducing its effective floor area. Hence, high-performance ...

2011
Jian Li Lijun Yang

Oil-impregnated paper is widely used in power transmission equipment as a reliable insulation. However, copper sulphide deposition on oil-paper insulation can lead to insulation failures in power transformers. This paper presents the influences of copper sulfur corrosion and copper sulphide deposition on copper wires and oil-paper insulation in power transformers. Thermal aging tests of paper-w...

1999
Kalev Kuklane Ingvar Holmér Gordon Giesbrecht

Moisture inside the footwear can considerably affect the thermal insulation. In this study with a thermal foot model there was simulated three sweat rates (3, 5 and 10 g/h). Five types of footwear with various insulation levels (dry insulation from 0.19 to 0.50 m2 · K/W) were tested. The footwear insulation reduction was calculated for 1.5 hour period. The reduction in insulation was related to...

ژورنال: انرژی ایران 2017

One of the most important energy-saving of building is suitable choice of insulation with regard to the climatic conditions of each region. In this study, the effects of building insulations approved by the Research Center of Way, Housing and Urban Development with regard to the cost of insulation on energy consumption in the region of Yazd, Tehran and Tabriz was evaluated by software Energy Pl...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید