نتایج جستجو برای: Air conditioning

تعداد نتایج: 247241  

Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...

Gaurav, R. Kumar,

Air conditioning refrigerant R134a has value of global warming potential (GWP) 1300, which is much higher than MAC Directive (GWP below 150) passed in July 2006. This prompted a search for alternative refrigerant with GWP value less than 150. R1234yf is a new refrigerant which has lower GWP value of 4. Effect of blower speed has been compared and flammability issue of R1234yf has been addre...

Journal: :international journal of automotive engineering 0
gaurav r. kumar

air conditioning refrigerant r134a has value of global warming potential (gwp) 1300, which is much higher than mac directive (gwp below 150) passed in july 2006. this prompted a search for alternative refrigerant with gwp value less than 150. r1234yf is a new refrigerant which has lower gwp value of 4. effect of blower speed has been compared and flammability issue of r1234yf has been addressed...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تربیت مدرس 1386

چکیده ندارد.

Journal: :journal of artificial intelligence in electrical engineering 2014
alireza soleimanzadeh

today air conditioning systems have been considered by all people as one of welfarerequirements in buildings and closed environments. since a considerable part of energy lossoccurs in ordinary modern systems, new strategies and solutions are developed in the field inorder to save amount of energy consumption and observe environmental considerations. fuzzycontrol is one of these methods which pr...

Journal: :international journal of advanced design and manufacturing technology 0
farshad panahizadeh navid bozorgan

the first and second laws of thermodynamics have been employed to evaluate energy and exergetic efficiency of the single effect absorption chiller which is used for air conditioning purpose. the performance analysis has been carried out by developing a computer program in ees and modeling the chiller and its components. to evaluate entropy of the water/lithium bromide solution at any point, an ...

1998
Mikio MATSUKI Norio TANAKA

The total power consumption of all semiconductor plants exceeds 100 million kWh per year, with about 43% of this consumption to operate air conditioning facilities. This high power consumption is due to the requirement of the cleanliness kept for clean rooms, with extremely high power consumed to the air transferring power. Oki developed the fan module unit (FMU) type air conditioning system to...

2014
JUNJI MORIKAWA SEIJI KONDO SHINICHI ISOZUMI CHUZO NINAGAWA

*1 Air-Conditioner Designing & Engineering Department, Air-Conditioning & Refrigeration Division *2 Manager, Air-Conditioner Designing & Engineering Department, Air-Conditioning & Refrigeration Division *3 Chief Staff Manager, Sales Department, Air-Conditioning & Refrigeration Division *4 Professor, Department of Electrical, Electronic and Computer Engineering, Faculty of Engineering, Gifu Univ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید