نتایج جستجو برای: AIDR

تعداد نتایج: 23  

2015
Sarah Feger Matthias Rief Elke Zimmermann Peter Martus Joanne Désirée Schuijf Jörg Blobel Felicitas Richter Marc Dewey

PURPOSE The aim of this study was the systematic image quality evaluation of coronary CT angiography (CTA), reconstructed with the 3 different levels of adaptive iterative dose reduction (AIDR 3D) and compared to filtered back projection (FBP) with quantum denoising software (QDS). METHODS Standard-dose CTA raw data of 30 patients with mean radiation dose of 3.2 ± 2.6 mSv were reconstructed u...

Journal: :The British journal of radiology 2012
F Tatsugami M Matsuki G Nakai Y Inada S Kanazawa Y Takeda H Morita H Takada S Yoshikawa K Fukumura Y Narumi

OBJECTIVE To evaluate the effect of adaptive iterative dose reduction (AIDR) on image noise and image quality as compared with standard filtered back projection (FBP) in 320-detector row CT coronary angiography (CTCA). METHODS 50 patients (14 females, mean age 68 ± 9 years) who underwent CTCA (100 kV or 120 kV, 400-580 mA) within a single heartbeat were enrolled. Studies were reconstructed wi...

2014
Milim Kim Jeong Min Lee Jeong Hee Yoon Hyoshin Son Jin Woo Choi Joon Koo Han Byung Ihn Choi

OBJECTIVE To evaluate the impact of the adaptive iterative dose reduction (AIDR) three-dimensional (3D) algorithm in CT on noise reduction and the image quality compared to the filtered back projection (FBP) algorithm and to compare the effectiveness of AIDR 3D on noise reduction according to the body habitus using phantoms with different sizes. MATERIALS AND METHODS Three different-sized pha...

Journal: :Diagnostic and interventional imaging 2014
A Gervaise B Osemont M Louis S Lecocq P Teixeira A Blum

PURPOSE To compare the dose and image quality of a standard dose abdominal and pelvic CT with Filtered Back Projection (FBP) to low-dose CT with Adaptive Iterative Dose Reduction 3D (AIDR 3D). MATERIALS AND METHODS We retrospectively examined the images of 21 patients in the portal phase of an abdominal and pelvic CT scan before and after implementation of AIDR 3D iterative reconstruction. Th...

Journal: :Medical physics 2016
J D Thompson D P Chakraborty K Szczepura A K Tootell I Vamvakas D J Manning P Hogg

PURPOSE To evaluate nodule detection in an anthropomorphic chest phantom in computed tomography (CT) images reconstructed with adaptive iterative dose reduction 3D (AIDR(3D)) and filtered back projection (FBP) over a range of tube current-time product (mAs). METHODS Two phantoms were used in this study: (i) an anthropomorphic chest phantom was loaded with spherical simulated nodules of 5, 8, ...

2017
Ahmed Fareed Andrea L. Vavere Elke Zimmermann Yutaka Tanami Chloe Steveson Matthew Matheson Narinder Paul Melvin Clouse Christopher Cox João A.C. Lima Armin Arbab-Zadeh

Iterative reconstruction has been shown to reduce image noise compared with traditional filtered back projection with quantum denoising software (FBP/QDS+) in CT imaging but few comparisons have been made in the same patients without the influence of interindividual factors. The objective of this study was to investigate the impact of adaptive iterative dose reduction in 3-dimensional (AIDR 3D)...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2014
Hiroaki Hasegawa Yoshiyuki Mihara Kenji Ino Jiro Sato

The purpose of this study was to evaluate the radiation dose reduction to patients and radiologists in computed tomography (CT) guided examinations for the thoracic region using CT fluoroscopy. Image quality evaluation of the real-time filtered back-projection (RT-FBP) images and the real-time adaptive iterative dose reduction (RT-AIDR) images was carried out on noise and artifacts that were co...

Journal: :Journal of neurosurgery 2016
Daan Backes Gabriel J E Rinkel Ale Algra Ilonca Vaartjes Gé A Donker Mervyn D I Vergouwen

OBJECTIVE This study investigated whether the increased incidence of aneurysmal subarachnoid hemorrhage (SAH) in winter is related to temperature or increased incidence of influenza. Such relationships may elucidate the pathogenesis of intracranial aneurysm rupture. METHODS A nationwide sample of 18,714 patients with SAH was linked with weekly temperature and influenza-like illness consultation...

C Anam, H Sutanto I Suyudi P Triadyaksa T Fujibuchi

Background: The HU linearity is an essential parameter in a quantitative imaging and the treatment planning systems of radiotherapy. Objective: This study aims to evaluate the linearity of Hounsfield unit (HU) in applying the adaptive iterative dose reduction (AIDR) on CT scanner and its comparison to the filtered back-projection (FBP).Material and Methods: In this experimental phan...

Journal: :Clinical case reports 2016
Etsuko Mizutamari Yuji Matsuo Tomohiro Namimoto Takashi Ohba Yasuyuki Yamashita Hidetaka Katabuchi

An important part of anti-N-methyl-d-aspartate (NMDA) receptor encephalitis treatment is prompt detection and removal of any associated ovarian teratoma, regardless of size. High-resolution transvaginal ultrasonography followed by targeted CT with adaptive iterative dose reduction (AIDR) is a useful strategy for distinguishing small ovarian teratomas from luteal cysts during pregnancy.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید