نتایج جستجو برای: 103Pd seed

تعداد نتایج: 76510  

2011
Pooneh Saidi Mahdi Sadeghi S. Hamed Hosseini Claudio Tenreiro

This work presents experimental dosimetry results for a new 103Pd brachytherapy seed, in accordance with the AAPM TG-43U1 recommendation that all new low-energy interstitial brachytherapy seeds should undergo one Monte Carlo (MC) and at least one experimental dosimetry characterization. Measurements were performed using TLD-GR200A circular chip dosimeters using standard methods employing thermo...

Journal: :Medical physics 2000
J F Williamson B M Coursey L A DeWerd W F Hanson R Nath M J Rivard G Ibbott

The National Institute of Standards and Technology (NIST) introduced a national standard for air kerma strength of the ThreaSeed Model 200 103Pd source (the only 103Pd seed available until 1999) in early 1999. Correct implementation of the NIST-99 standard requires the use of dose rate constants normalized to this same standard. Prior to the availability of this standard, the vendor's calibrati...

2007
Sharifeh A. Dini Shahid B. Awan Kai Dou Ali S. Meigooni

Recently, to eliminate problems associated with seed type sources, RadioMed Corporation (Tyngsboro, MA) introduced RadioCoil 103Pd sources for interstitial prostate implants. The RadioCoil sources are available in integral lengths ranging from 1.0 cm to 6.0 cm. In this project, dosimetric characteristics of these sources were determined following the TG-43U1 recommendations, with consideration ...

2017
A. A. Mowlavi

Theoretical and experimental dosimetric studies have been supplied useful information on the dependence of the brachytherapy source geometry and materials (1-5). Usually, Monte Carlo method is used to define dose distribution function, the radial dose variation, and the dose calculation close to the source in brachytherapy. Chen et al. (6). calculated the distribution of absorbed dose around co...

Journal: :Medical physics 2006
Ali S Meigooni Shahid B Awan Kai Dou

Recently, elongated brachytherapy sources (active length >1 cm) have become commercially available for interstitial prostate implants. These sources were introduced to improve the quality of brachytherapy procedures by eliminating the migration and seed bunching associated with loose seed-type implants. However, the inability to calibrate elongated brachytherapy sources with the Wide-Angle Free...

Journal: :Environmental Health Perspectives 1975
W Moore D Hysell L Hall K Campbell J Stara

Preliminary data are given on the LD50 of PdCl2 following different routes of exposure and on the LD50 of PtCl4 following intravenous exposure. The retention, tissue distribution, and excretion of 103Pd and 191Pt in rats was determined following oral, intravenous, intratracheal, and inhalation exposure. The highest retention for both 103Pd and 191Pt was obtained following intravenous dosing, an...

2016
Somayeh Asadi Mehdi Vaez‐zadeh Mohammad Vahidian Mahdieh Marghchouei S. Farhad Masoudi

The aim of the present Monte Carlo study is to evaluate the variation of energy deposition in healthy tissues in the human eye which is irradiated by brachytherapy sources in comparison with the resultant dose increase in the gold nanoparticle (GNP)-loaded choroidal melanoma. The effects of these nanoparticles on normal tissues are compared between 103Pd and 125I as two ophthalmic brachytherapy...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2001
M J Rivard

It is of interest to discern the energy-dependence of American Association of Physicists in Medicine (AAPM) TG-43 brachytherapy dosimetry parameters. Using Monte Carlo calculation geometry and techniques (MCNP), dependence of these parameters was calculated as a function of photon energy, in general, and for the MED3633 103Pd source using a discretized approach. Results were weighted and summed...

2017
H. Rezaei H. Mostaghimi A.R. Mehdizadeh

BACKGROUND A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC) is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet. OBJECTIVE The present study aims to modify source strength for different configurations of 125I and 103Pd...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید