نتایج جستجو برای: transformer protection scheme
تعداد نتایج: 408229 فیلتر نتایج به سال:
Transformers By-Example (TBE) is a concept that facilitates the definition and application of scheme transformers. When defining a conceptual scheme modelers can use scheme transformers, which transform an input scheme into an extended or refined output scheme, for automatically performing modelling tasks. An exemplary modelling task in the sphere of web application modelling is "after having d...
More and more sub-stations are retrofitted with numerical relays, meters and monitoring devices. Most often, the older relay gets replaced with a newer relay with the rest of the installation such as Current Transformer (CT) and lead remaining undisturbed. Utilities have standardized on their older current transformers and want to maintain the same current transformer specifications throughout ...
In this paper, a new algorithm based on processing differential current harmonics is proposed for digital differential protection of power transformers. This algorithm has been developed by considering different behaviors of second harmonic components of the differential currents under fault and inrush current conditions. In the new method, a criterion function is defined in terms of the time v...
This paper proposes a method to obtain a protected voltage gain by employing a protection circuit for the voltage doubler or multiplier circuit in an isolated tyde DC-DC Converter. The entire set up consists of a phase shift converter with a protected bridge/voltage doubler rectifier on the output side. The operating frequency of the phase shift converter is 20-25kHz (depending on the requireme...
this paper presents the application of the fuzzy-neuro method toinvestigate transformer inrush current. recently, the frequency environment ofpower systems has been made more complicated and the magnitude of the secondharmonic in inrush current has been decreased because of the improvement of caststeel. therefore, traditional approaches will likely mal-operate in the case ofmagnetizing inrush w...
The failure of a large power transformer is an area of significant concern since it can result in millions of dollars in costs as well as a possible interruption of power. Therefore, it is desirable to detect the existence of abnormal or anomalous changes in the transformer's internal condition which could indicate an incipient failure. This thesis proposes and tests an anomaly detection scheme...
protection systems have vital role in network reliability in short circuit mode and proper operating for relays. current transformer often in transient and saturation under short circuit mode causes mal-operation of relays which will have undesirable effects. therefore, proper and quick identification of current transformer saturation is so important. in this paper, an artificial neural network...
The development of the transformer insulation failure undergoes three stages: insulation aging, incipient faults and a short circuit. This paper presents a complete scheme to simulate single-phase transformers with insulation deterioration and arcing phenomena i.e. in the first two stages. The approach incorporates Transmission Line Methods (TLM), Jiles-Atherton Hysteretic Model, Composite Cass...
The development of the transformer insulation failure undergoes three stages: insulation aging, incipient faults and a short circuit. This paper presents a complete scheme to simulate single-phase transformers with insulation deterioration and arcing phenomena i.e. in the first two stages. The approach incorporates Transmission Line Methods (TLM), Jiles-Atherton Hysteretic Model, Composite Cass...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید