نتایج جستجو برای: tibial fracture surgery

تعداد نتایج: 439377  

2012
Tanawat Vaseenon Sirichai Luevitoonvechkij Anupong Laohapoonrungsee

Tibial shaft fracture is a common orthopaedic and trauma condition. Incidence of tibial fracture is average 26 in 100,000 per year at the age of 15 to 19 years. It is more common in US that is 109 in 100,000 per year [1]. Operative treatment options are external fixation, open reduction and internal fixation with plate and screws or intramedullary nailing. Intramedullary nailing is widely accep...

2013
Hossein Aslani Ali Tabrizi Ali Sadighi Ahmad Reza Mirblok

BACKGROUND Tibial fractures are the third most common pediatric long-bone fracture after forearm and femoral fractures. Approximately 50% of pediatric tibial fractures occur in the distal third of the tibia. This is followed by midshaft tibial fractures (39%), and least commonly, the proximal third of the tibia is involved. Tibial fractures in the skeletally immature patient can usually be trea...

Journal: :Journal of clinical and diagnostic research : JCDR 2015
Ravi Mahalingappa Daddimani Srinath Kadagattur Madhavamurthy Santosh Somayya Jeevannavar Chidendra Manohar Shettar

The sesamoid bone ligament complex of foot contains two sesamoid bones one medial tibial sesamoid and other lateral fibular sesamoid bone, both embedded in the plantar ligament beneath first metatarsal head. The incidence of medial tibial sesamoid bone fracture is rare. Clinically they are often misdiagnosed as soft tissue injuries and often missed. We present a case of fracture medial tibial s...

2009
Hong Chul Lim Ji Hoon Bae Jin Ho Hwang Seung Joo Kim Ji Yeol Yoon

We report the case of a polyethylene tibial post fracture in a 72-year-old woman 14 months after a Scorpio posterior-stabilized (PS) total knee arthroplasty. The polyethylene wear was found around the fracture site of the post, especially over the anterior aspect of the post base. The failure mechanism of the post fracture in the present case was anterior impingement with excessive wear over th...

Journal: :Orthopaedics & traumatology, surgery & research : OTSR 2015
X Roussignol G Sigonney D Potage M Etienne F Duparc F Dujardin

INTRODUCTION Secondary intramedullary nailing (SIN) following external fixation (EF) of tibial shaft fracture is controversial, notably due to the infection risk, which is not precisely known. The present study therefore analysed a continuous series of tibial shaft SIN, to determine (1) infection and union rates, and (2) whether 1-stage SIN associated to EF ablation increased the risk of infect...

2016
Jing-Wei Zhang Nabil A. Ebraheim Ming Li Xian-Feng He Joshua Schwind Li-Mei Zhu Yi-Hui Yu

OBJECTIVE To evaluate the feasibility and efficiency of one-stage external fixation by using locking plate in distal tibial fractures. METHODS In this non-control prospective study, 28 patients with distal tibial fractures were included and underwent one-stage external fixation by using locking plate. There were 21 males and 7 females, with a mean age of 43 years (19-63). According to AO/OTA ...

Journal: :Singapore medical journal 2012
Weiliang Chua Diarmuid Murphy Weiming Siow Fareed Kagda Joseph Thambiah

INTRODUCTION Open fractures of the tibia pose a challenge to orthopaedic and plastic surgeons. A retrospective observational review was conducted to evaluate the epidemiological factors and fracture outcomes in the Singapore context. METHODS A nine-year period of open tibial shaft fractures presenting to our institution was reviewed. Demographic and management data were recorded. Statistical ...

2015
Tsan-Wen Huang Chien-Ying Lee Szu-Yuan Chen Shih-Jie Lin Kuo-Yao Hsu Robert Wen-Wei Hsu Yi-Sheng Chan Mel S. Lee

BACKGROUND Tibial eminence avulsion fracture often co-occurs with tibial plateau fracture, which leads to difficult concomitant management. The value of simultaneous arthroscopy-assisted treatment continues to be debated despite its theoretical advantages. We describe a simple arthroscopic suture fixation technique and hypothesize that simultaneous treatment is beneficial. METHODS Patients wi...

2010
Lucian B Solomon Aaron W Stevenson Stuart A Callary Thomas R Sullivan Donald W Howie Mellick J Chehade

BACKGROUND AND PURPOSE The application of radiostereometric analysis (RSA) to monitor stability of tibial plateau fractures during healing is both limited and yet to be validated. We therefore evaluated the accuracy and precision of RSA in a tibial plateau fracture model. METHODS Combinations of 3, 6, and 9 markers in a lateral condyle fracture were evaluated with reference to 6 proximal tibi...

Journal: :Injury 2009
S Badhe D Baiju R Elliot J Rowles D Calthorpe

Intractable pain out of proportion to the injury sustained is considered to be the earliest and most reliable indicator of a developing compartment syndrome. We report 4 cases where competent sensate patients developed compartment syndromes without any significant pain. The first patient developed a painless compartment syndrome in the well leg following surgery for femoral fracture on the othe...

نمودار تعداد نتایج جستجو در هر سال