نتایج جستجو برای: shunt active power filter sapf
تعداد نتایج: 1024582 فیلتر نتایج به سال:
The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...
DYNAMIC PERFORMANCE OPTIMIZATION OF SHUNT ACTIVE POWER FILTER TO ELIMINATE TOTAL HARMONIC DISTORTION
In this paper, a proposed efficient solution for an important power quality problem focused on harmonic distortion in the source current is introduced by using Shunt Active Power Filter (SAPF) controlled sinusoidal control strategy which based instantaneous active and reactive theory (Sinusoidal PQ-theory). As part of controller, there PI-Controller enhances APF controller performance when tuni...
This paper presents a comparative analysis between two current control strategies, constant source power and generalized Fryze current, used in Active Power Filter (APF) applications having three different modulation methods. The Hysteresis Band (HB) and first-order Delta-Sigma Modulation (DSM) as well as the second-order DSM is applied. The power section of the active power filter is viewed as...
This paper presents a fuzzy logic, PI controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Variable load condi...
This paper shows the method of improving the power quality using shunt active power filter. The proposed topic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is from hysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. This paper repr...
This paper describes a novel fuzzy logic controller for a three phase shunt active shunt filter for the power quality improvement. The Power Quality (PQ) problems in power distribution systems are not new but only recently the effects of these problems have gained public awareness. These non-linear loads are constructed by nonlinear devices in which the current is not proportional to the applie...
This paper proposes a new method of sliding mode base controller for shunt active power filter to compensate the harmonic currents of a load. In this controller there isn't any need to PI DC voltage controller to regulate the DC capacitor voltage of shunt active power filter. In this method, first the reference currents of shunt active power filter that should be tracked to reduce or eliminate ...
This paper describes the application of a new fuzzy based control strategy to a three-phase shunt active power filter for harmonics minimization and reactive power compensation required by a variable non-linear load. To improve dynamic behaviour of shunt active power filter and make it robust under wide range of load variations, the value of load current is considered as an input of fuzzy contr...
Due to large amount of non-linear power electronic equipment’s impact and fluctuating loads, problems of power quality have become more and more serious with each passing day. Active power filtering has gained much more importance in the power quality arena as it gives the best solution for all power quality issues. Shunt active filtering is effective and the performance of such units largely d...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید