نتایج جستجو برای: septal occluder device
تعداد نتایج: 705866 فیلتر نتایج به سال:
Percutaneous closure of secundum atrial septal defects (ASD) may be complicated by immediate embolization. We report on a 35-year-old woman who underwent percutaneous device closure for a secundum ASD. The diameter of the defect was measured as 4 mm by two-dimensional transesophageal echocardiography and a 7-mm Figulla ASD occluder device was implanted without prior balloon sizing of the defect...
We describe a 17-year-old patient with an atrial septal defect who underwent device closure with a second generation Sideris buttoned device at 4 years of age. She presented 13 years after the procedure with the acute onset of chest discomfort, at which time a chest radiograph showed migration of the wire of the right atrial counter-occluder to the lateral aspect of the right atrial wall, with ...
We report the case of a 72-year-old woman diagnosed with ostium secundum atrial septal defect (OS-ASD) in an echocardiogram performed as part of the work-up for her high blood pressure. Over time, progressive dilation of the right ventricle was observed with progressive functional deterioration, indicating closure of the defect. Transesophageal echocardiography (TEE) confirmed an OS-ASD of 15×1...
A 39-year-old woman underwent uneventful percutaneous occlusion of an ostium secundum atrial septal defect (ASD) with a 22 mm Ultrasept ASD Occluder®. Transesophageal echocardiography (TEE) performed two years after implantation revealed a de novo residual left-to-right shunt through the correctly implanted device. Three-dimensional transesophageal echocardiography (3D TEE) further clarified th...
Paravalvular leak following a mitral valve replacement is a complication seen in approximately 1 of 10 replacements. The corrective method has traditionally been reoperation. Septal occluder devices are more commonly being utilized as an alternative percutaneous correction method. We report the use of septal occluder devices in the repair of mitral paravalvular leak in two patients at severely ...
INTRODUCTION The purpose of this study was to investigate the clinical value of real-time three-dimensional transesophageal echocardiography (RT-3D-TEE) for percutaneous transcatheter closure of multiple secundum atrial septal defects (ASDs) using a Chinese domestic occluder device. METHODS From July 2008 to September 2011, 37 patients (mean age 28.4 ± 9.7 years; 24 females) with multiple sec...
Percutaneous device closure of atrial septal defect (ASD) is an alternative treatment to surgery. The main advantages of the percutaneous approach include avoidance of surgery, short procedure time and hospital length, in addition to comparable rates of complications. However, percutaneous device closure is associated with infrequent early and late complications including device embolization, a...
A 21-year-old female patient was transferred to our hospital after being diagnosed with massive pulmonary thromboembolism (PTE). Three years prior to admission, she underwent transcatheter closure of the secundum ASD with a 33 mm CardioSEAL-StarFLEX occluder (NMT Medical, Boston, MA, USA). A year ago, she was involved in a car accident and sustained significant blunt chest trauma. Transthoracic...
OBJECTIVES The aim of this study was to assess long-term results of percutaneous closure of secundum-type atrial septal defect (ASD II) using Amplatzer septal occluders (ASO). BACKGROUND Only immediate-, short-, and intermediate-term results of ASO implantation are known so far. METHODS Between September 1995 and January 2000, 151 patients underwent a successful percutaneous closure of ASD ...