نتایج جستجو برای: retinal nerve fiber layer

تعداد نتایج: 618734  

Journal: :American journal of ophthalmology 1973
D R Anderson

The axons that make up the optic nerve originate from the retinal ganglion cells and extend from there to the lateral geniculate body. If cellular integrity is interrupted by disease anywhere along the course of an axon, degeneration occurs in both directions from the point of insult. Thus, axon frag­ ments between the site of injury and the lat­ eral geniculate body are separated from their nu...

Journal: :journal of current ophthalmology 0
محمدمهدی پرورش mohammad-mehdi parvaresh مرجان ایمانی marjan imani محسن بهمنی کشکولی mohsen bahmani-kashkouli مصطفی سلطان سنجری mostafa soltan-sanjari

purpose : to determine the nerve fiber layer and macular thickness by optical coherence tomography (oct) in emmetropic, high-myopic and high-hyperopic eyes methods : one hundred five eyes of 55 randomly selected healthy subjects between 20 and 30 years old were included in this study. the eyes were categorized in three groups (high-myopic, emmetropic and high-hyperopic) according to their cyclo...

Journal: :Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians 2009
Juan M Bueno Christopher J Cookson Jennifer J Hunter Marsha L Kisilak Melanie C W Campbell

The degree of polarization (DOP) of the light reflected from the optic nerve head has been assessed by means of a polarimetric scanning laser ophthalmoscope as a function of the age of the participants. Four fundus images corresponding to independent polarization states in the recording pathway were used to compute the spatially-resolved DOP. This was not uniform across the optic nerve head and...

Journal: :Investigative ophthalmology & visual science 2009
Folkert K Horn Christian Y Mardin Robert Laemmer Delia Baleanu Anselm M Juenemann Friedrich E Kruse Ralf P Tornow

PURPOSE To study the correlation between local perimetric field defects and glaucoma-induced thickness reduction of the nerve layer measured in the peripapillary area with scanning laser polarimetry (SLP) and spectral domain optical coherence tomography (SOCT) and to compare the results with those of a theoretical model. METHODS The thickness of the retinal nerve fiber layer was determined in...

Journal: :JAMA ophthalmology 2015
Edward D Plowey Peter R Egbert

IMPORTANCE Retinal hemorrhages are an important sequela of fatal head trauma. The accurate pathologic diagnosis of retinal hemorrhages has critical implications for determination of the manner of death. OBSERVATIONS We describe an autolytic postmortem histologic artifact of eosinophilic Müller cell foot process swelling that mimics a nerve fiber layer hemorrhage. From April 24, 2012, through ...

Journal: :The British journal of ophthalmology 1998
J E Morgan A Waldock G Jeffery A Cowey

AIMS To compare histological thickness of the retinal nerve fibre layer in the primate with retardation measurements obtained in vivo using the Mark II Nerve Fiber Analyzer (NFA, Laser Diagnostic Technologies, San Diego, USA). METHODS Scanning laser polarimetry was performed on both eyes of a healthy anaesthetised adult primate (Macaca mulatta). The retinal nerve fibre layer thickness was mea...

2011
Seiji T. Takagi Yoshiyuki Kita Asuka Takeyama Goji Tomita

Purpose. To evaluate the relationship between the macular ganglion cell complex (mGCC) thickness, which is the sum of the retinal nerve fiber, ganglion cell, and inner plexiform layers, measured with a spectral-domain optical coherence tomograph and the optic nerve head topography measured with a confocal scanning laser ophthalmoscope in glaucomatous eyes with visual field defects localized pre...

Journal: :Arquivos brasileiros de oftalmologia 2015
İsa Yuvacı Emine Pangal Yudum Yüce Sümeyra Yuvacı Nurettin Bayram Döndü Melek Ulusoy Ali Akal Orhan Altunel

PURPOSE Optic coherence tomography (OCT) evaluation of the choroid, retina, and retinal nerve fiber layer after uncomplicated yttrium-aluminum-garnet (YAG) laser capsulotomy. METHODS OCT analysis of retinal and choroidal structures was performed in 28 eyes of 28 patients following routine examinations before and 24 h, 72 h, 2 weeks, 4 weeks, and 12 weeks after YAG laser capsulotomy. Data were...

2017
Sieun Lee Morgan L. Heisler Karteek Popuri Nicolas Charon Benjamin Charlier Alain Trouvé Paul J. Mackenzie Marinko V. Sarunic Mirza Faisal Beg

Optical coherence tomography provides high-resolution 3D imaging of the posterior segment of the eye. However, quantitative morphological analysis, particularly relevant in retinal degenerative diseases such as glaucoma, has been confined to simple sectorization and averaging with limited spatial sensitivity for detection of clinical markers. In this paper, we present point-wise analysis and vi...

Journal: :Arquivos brasileiros de oftalmologia 2012
Daniela Araújo Toscano Marcos Pereira de Ávila Maria Regina Catai Chalita

PURPOSE To evaluate the reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness measurements in normal eyes and eyes with glaucoma using spectral domain optical coherence tomography (SDOCT). METHODS One eye of 79 normal and 72 glaucoma patients was analyzed. All patients underwent a complete ophthalmological examination, including visual acuity testing; intraocular pressur...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید