نتایج جستجو برای: respiratory protective device
تعداد نتایج: 979989 فیلتر نتایج به سال:
INTRODUCTION Ventilator-associated pneumonia (VAP) may contribute to the mortality associated with acute respiratory distress syndrome (ARDS). We aimed to determine the incidence, outcome, and risk factors of bacterial VAP complicating severe ARDS in patients ventilated by using a strictly standardized lung-protective strategy. METHODS This prospective epidemiologic study was done in all the ...
Extracorporeal CO2 removal (ECCO2R) is a therapeutic approach that allows protective ventilation in acute respiratory failure by preventing hypercapnia and subsequent acidosis. The main indications for ECCO2R are COPD (chronic obstructive pulmonary disease) exacerbation, distress syndrome (ARDS) other situations of asthmatics status. However, procedure not extended to those ARDS patients presen...
Introduction: The World Health Organization released recommendations including social distancing, use of personal protective equipment, and respiratory hygiene to decrease the risk coronavirus disease (COVID-19).
Magnetic fields generated by the brain or the heart are very useful in clinical diagnostics. Therefore, magnetic signals produced by other organs are also of considerable interest. Here we show first evidence that thoracic muscles can produce a strong magnetic flux density during respiratory activity, that we name respiratory magnetogram. We used a small magnetometer based on microelectromechan...
This article aims to characterize the mechanical behaviour of the Flutter VRP1, a respiratory physiotherapy device designed to aid sputum clearance of the airways of patients. The device resembles a smoking pipe with a conical cavity containing a stainless steel sphere which floats up and down while the patient comes with a forced expiration through it. The sphere's oscillatory movement is func...
OBJECTIVE To evaluate breathing pattern and thoracoabdominal motion during breathing exercises. METHODS Twenty-four patients with class II or III obesity (18 women; 6 men) were studied on the second postoperative day after gastroplasty. The mean age was 37 +/- 11 years, and the mean BMI was 44 +/- 3 kg/m(2). Diaphragmatic breathing, incentive spirometry with a flow-oriented device and incenti...
The search for a reliable and accurate respiratory rate monitor for use in non-intubated patients has proved to be a long and fruitless one. A new device fulfilling the criteria for such a monitor has recently been described. The pyroelectric polymer (PEP) device is safe, non-invasive, and cheap. In this study the PEP device, transthoracic impedance, and standard observer counting were all comp...
The present study describes a device (AMD43) for ambulatory measurement of respiration rate and respiratory sinus arrhythmia from the combined electrocardiogram (ECG) and thoracic impedance signals. Respiratory time intervals derived from this ambulatory device closely corresponds to those derived from simultaneous recordings with a 'classical' laboratory set-up. Good cross-instrument compariso...
We investigated the contributions of the structural proteins of severe acute respiratory syndrome (SARS) coronavirus (CoV) to protective immunity by expressing them individually and in combinations from a recombinant parainfluenza virus (PIV) type 3 vector called BHPIV3. This vector provided direct immunization of the respiratory tract, the major site of SARS transmission, replication, and dise...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید