نتایج جستجو برای: pvc membrane electrode

تعداد نتایج: 452869  

2006
M. R. Ganjali

In this paper, a novel membrane triiodide sensor based on a charge-transfer complex of (1,3-diphenyldihydro-1H-imidazole-4,5-dionedioxime) with iodine (CTCI) as a membrane carrier is introduced. The best performance was obtained with a membrane containing 30% polyvinylchloride (PVC), 63% dibutylphthalate (DBP), 5% CTCI and 2% hexadecyltrimethylammonium bromide (HTAB). The electrode shows a Nern...

Ali Reza Abedin Hossein Aghaie Karim Zare, Mehran Aghaie

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

Journal: :journal of physical & theoretical chemistry 2008
n. farahani h. aghaie

fe2+ ion-selective membrane sensor has been fabricated from polyvinyl chloride (pvc) matrixmembrane containing neutral carrier tetra phenyl porphyrin (tpp) ionophore. the addition ofsodium tetraphenylborate (natpb) and the plasticizer dbp has been found to substantiallyimprove the performance of the sensor. the best performance was obtained with the sensor havinga membrane of composition of tpp...

Journal: :journal of membrane science and research 0
iman khalilinejad membrane processes research laboratory (mprl), department of chemical engineering, amirkabir university of technology (tehran polytechnic), mahshahr campus, mahshahr, p.o. box 415, iran hamidreza sanaeepur membrane processes research laboratory (mprl), department of chemical engineering, amirkabir university of technology (tehran polytechnic), mahshahr campus, mahshahr, p.o. box 415, iran ali kargari membrane processes research laboratory (mprl), department of chemical engineering, amirkabir university of technology (tehran polytechnic), mahshahr campus, mahshahr, p.o. box 415, iran

in this work, novel thin film composite membranes (tfcs) of poly (ether-6-block amide) (pebax-1657) on a polyvinyl chloride (pvc) ultrafiltration membrane as support were prepared using inclined coating method for co2 separation. investigating the effects of top selective layer thickness formed by controlling the coating angle (15-60°) and polymer solution concentration (5-10 wt.%), and also, t...

2013
Farhad Ahmadi Nasim Asaadi

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09-5586 μg ...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Mohammad Reza Ganjali Mahmood Golmohammadi Mohammad Yousefi Parviz Norouzi Masoud Salavati-Niasari Mehran Javanbakht

A copper(II) ion-selective PVC membrane sensor based on 2-(1'-(4'-(1''-hydroxy-2''-naphthyl)methyleneamino)butyl iminomethyl)-1-naphthol (BHNB) as a novel Schiff base containing a sensing material has been successfully developed. The sensor exhibits a good linear response of 29 mV per decade within the concentration range of 10(-1)-10(-6) M of Cu2+. The sensor shows good selectivity for copper(...

2011
Hassan Ali Zamani

A PVC-membrane ion-selective electrode was constructed for quantitative monitoring of gadolinium(III) ion based on 3-methyl-1H-1,2,4-triazole-5-ylhydrosufide (MTY) as an ion carrier. The electrode performance includes a Nernstian slope of 19.8 ± 0.4 mV per decade across a wide concentration range between 1.0 × 10 and 1.0 × 10 M and a detection limit of 7.3 × 10 M. The best performance was obtai...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2009
Ayman H Kamel Sofia A A Almeida M Goreti F Sales Felismina T C Moreira

New PVC membrane electrodes for the determination of sulfadiazine (SDZ) are presented. The electrodes are fabricated with conventional and tubular configurations with a graphite-based electrical contact, and no internal reference solution. The selective membranes consist of bis(triphenylphosphoranilidene)ammonium.SDZ (electrode A), tetraoctylammonium bromide (electrode B), or iron(II)-phthalocy...

2015
Mohamed M. Khalil Yousry M. Issa Sahar M. Mostafa

A new pyrilamine coated graphite electrode (CGE) based on pyrilamine-tetraphenylborate ion-pair (Pyra-TPB) as electroactive material has been described. The sensor exhibited a linear response with a good Nernstian slope over a relatively wide range of concentration. The membrane film of the electrode made of 3% (w/w) ion-pair, 48.5% DBP (w/w) and 48.5% PVC (w/w). The sensor displays Nernstian r...

2008
Mohamed Rozali Othman

A study was carried out to characterize Ni-Co-PVC and Ni-Cu-PVC composite materials prepared by mechanical alloying technique (MAT) using SEM, EDS and electrochemical test. Composite materials were prepared by mixing together 95% of metal powder (Ni+Co or Ni+Cu) with 5% PVC. PVC was used as a binder and tetrahydrofuran (THF) was used as a solvent in composite material preparation. Based on the ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید