نتایج جستجو برای: pulse oximetry signal

تعداد نتایج: 499341  

Journal: :Journal of Clinical Sleep Medicine 2018

Journal: :Journal of Medical Devices 2009

Journal: :Thorax 2011
J-P Janssens J-C Borel J-L Pépin

Complex respiratory events, which may have a detrimental effect on both quality of sleep and control of nocturnal hypoventilation, occur during sleep in patients treated by non-invasive ventilation (NIV). Among these events are patient-ventilator asynchrony, increases in upper airway resistance with or without increased respiratory drive, and leaks. Detection of these events is important in ord...

Journal: :Anaesthesia and Intensive Care 2003

Journal: :Journal of Paramedic Practice 2018

Journal: :Lancet 2014
Qu-ming Zhao Xiao-jing Ma Xiao-ling Ge Fang Liu Wei-li Yan Lin Wu Ming Ye Xue-cun Liang Jing Zhang Yan Gao Bing Jia Guo-ying Huang

BACKGROUND Several pioneering studies have provided evidence for the introduction of universal pulse oximetry screening for critical congenital heart disease. However, whether the benefits of screening reported in studies from high-income countries would translate with similar success to low-income countries is unknown. We assessed the feasibility and reliability of pulse oximetry plus clinical...

2014
Meir Nitzan Ayal Romem Robert Koppel

Oxygen saturation in the arterial blood (SaO2) provides information on the adequacy of respiratory function. SaO2 can be assessed noninvasively by pulse oximetry, which is based on photoplethysmographic pulses in two wavelengths, generally in the red and infrared regions. The calibration of the measured photoplethysmographic signals is performed empirically for each type of commercial pulse-oxi...

2015
Alper Bozkurt James Dieffenderfer Jose Sarmiento Henry Goodell Feiyan Lin

Statement of Project Goals: 1. Design and assemble the Generation 0 (Gen 0) Health and Environmental Tracker (HET) testbed device to provide a baseline measurement platform to benchmark the improvements in Generation 1 (Gen 1) system in terms of power consumption, signal to noise ratio, sensor performance and size. The HET testbed includes a wristband and a chest patch. Obtain IRB approval and ...

Journal: :British journal of anaesthesia 2014
T E Morey M J Rice T Vasilopoulos D M Dennis R J Melker

BACKGROUND The nasal ala is an attractive site for pulse oximetry because of perfusion by branches of the external and internal carotid arteries. We evaluated the accuracy of a novel pulse oximetry sensor custom designed for the nasal ala. METHODS After IRB approval, healthy non-smoking subjects [n=12; aged 28 (23-41) yr; 6M/6F] breathed hypoxic mixtures of fresh gas by a facemask to achieve ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید