نتایج جستجو برای: pulse oximeter

تعداد نتایج: 90424  

Journal: :JAPANES JOURNAL OF MEDICAL INSTRUMENTATION 1987

Journal: :The European respiratory journal 1998
F Chiappini L Fuso R Pistelli

The aim of the present study was to evaluate the accuracy, in comparison with a reference method, of the Nellcor N-20P pulse oximeter in the assessment of oxyhaemoglobin saturation (Sa,O2). Sa,O2 was monitored at rest by the Nellcor N-20P pulse oximeter in 100 subjects (82 males, mean age 68+/-12 yrs) consecutively enroled. At the same time, an arterial blood sample was collected for the measur...

Journal: :Archives of emergency medicine 1989
C J Holburn M J Allen

The early detection and treatment of hypoxia is important to reduce patient morbidity in the accident and emergency department. At present, the commonly used methods all have practical difficulties in the urgent situations that prevail in the department. Pulse oximetry has recently become a method of choice in many anaesthetic and intensive care units for the continuous monitoring of oxygenatio...

Journal: :Pediatric pulmonology 2012
Jason B Caboot Abbas F Jawad Joseph M McDonough Cheryl Y Bowdre Raanan Arens Carole L Marcus Thornton B A Mason Kim Smith-Whitley Kwaku Ohene-Frempong Julian L Allen

Assessment of oxyhemoglobin saturation in patients with sickle cell disease (SCD) is vital for prompt recognition of hypoxemia. The accuracy of pulse oximeter measurements of blood oxygenation in SCD patients is variable, partially due to carboxyhemoglobin (COHb) and methemoglobin (MetHb), which decrease the oxygen content of blood. This study evaluated the accuracy and reliability of a non-inv...

2016
P. A. Kyriacou K. Shafqat S. K. Pal

Photoplethysmography is a non-invasive electro-optical technique widely used in the study and monitoring of the pulsations associated with changes in blood volume in a peripheral vascular bed. Photoplethysmography is used in the estimation of arterial oxygen saturation (SpO2) by pulse oximetry. A reflectance finger photoplethysmographic (PPG) probe and a multiplexed data acquisition system oper...

Journal: :CoRR 2010
Sangeeta Soni Yogendra Namjoshi

The non-invasive pulse-oximeter is a crucial parameter in continuous monitoring systems. It plays a vital role from admission of the patient to surgeries with general anaesthesia. The paper proposes the application of wavelet transform to delineate the raw plethysmograph signals obtained from basic portable and mobile-powered electronic hardware. The paper primarily focuses on finding peaks and...

عادلی, سیدحسن, اکبری, حسین , دادخواه تهرانی, تهمینه , روشنی مبارکی, سکینه , نراقی پورآرانی, زهرا , واحدیان, مصطفی , یگانه‌خواه, محمدرضا ,

Background and Objectives: Pulse oximetry is the most common technique for monitoring hemoglobin oxygen saturation (SpO2). Different colors and brands of nail polish may cause disturbance in the reading and interpretation of oxygen saturation. The aim of this study was to determine the effect of different colors of nail polish on oxygen saturation measured by pulse oximeter. Methods: Thirty he...

Journal: :Thorax 1987
A R Warley J H Mitchell J R Stradling

Arterial oxygen saturation values (Sao2) from 60% to 98% were measured by the Ohmeda 3700 pulse oximeter with the three types of probe available and compared with values of oxygen saturation estimated from direct arterial sampling (arterial oxygen and carbon dioxide tensions and pH) on 65 occasions. The response time of the oximeter was measured after a sudden rise in inspired oxygen concentrat...

2015
Tomoki Kohyama Kiyoshi Moriyama Riichiro Kanai Mariko Kotani Kohji Uzawa Toru Satoh Tomoko Yorozu

There is an error in the first three sentences under the subheading “Cut-Off value of SpO2” in the Results section. The correct sentences are: We hypothesized that the cut-off value of each pulse oximeter to detect hypoxemia (SaO2< = 90% or PaO2< = 60 mmHg) was different. We calculated the sensitivity, specificity, PPV, and NPV of each pulse oximeter to detect hypoxemia. As shown in Table 5, th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید