نتایج جستجو برای: polyether ether ketone
تعداد نتایج: 30560 فیلتر نتایج به سال:
Abstract Stress shielding is known to cause bone refracture or low healing rate in fractured bones. The numerical study of process a transverse tibia was conducted this research reduce the stress shielding. and strain on callus were evaluated when plates different metallic non-metallic biomaterials used. Time varying material properties applied, loading conditions coupled with callus. distribut...
The fatigue behavior of polyether ether ketone (PEEK) thermoplastic was investigated under uniaxial strain-controlled cyclic loading condition with various mean strains (Rε 1⁄4 0, 0.2, and 0.25). The mean stress responses of PEEK from all mean strain fatigue tests were found to be fully-relaxed. As a result, minimum mean strain effect on fatigue behavior of PEEK was observed. Fractography analy...
Polyether ether ketone (PEEK) is considered the best alternative material for titanium for spinal fusion cage implants due to its low elasticity modulus and radiolucent property. The main problem of PEEK is its bioinert properties. Coating with hydroxyapatite (HA) showed very good improvement in bioactivity of the PEEK implants. However the existing methods for deposition of HA have some disadv...
Despite its widespread clinical use in load-bearing orthopedic implants, polyether-ether-ketone (PEEK) is often associated with poor osseointegration. In this study, a surface-porous PEEK material (PEEK-SP) was created using a melt extrusion technique. The porous layer was 399.6±63.3 μm thick and possessed a mean pore size of 279.9±31.6 μm, strut spacing of 186.8±55.5 μm, porosity of 67.3±3.1% ...
PURPOSE The surgical management of the patients with traumatic sternal fractures remains controversial. The aim of this study was to evaluate the effectiveness of an early surgical reconstruction of a displaced sternal fracture utilizing longitudinal rigid polymer fixation in the settings of an acute chest trauma. METHODS To perform the sternal fixation, we utilized a longitudinal rigid plati...
In this study electrospun nanofibers of partially sulfonated polyether ether ketone have been produced as a preliminary step for a possible development of composite proton exchange membranes for fuel cells. Response surface methodology has been employed for the modelling and optimization of the electrospinning process, using a Box-Behnken design. The investigation, based on a second order polyn...
The ease and low environmental impact of its preparation, the reduced fuel crossover, cost, make sulfonated polyether ether ketone (sPEEK) a potential candidate to replace Nafion ionomer in proton exchange membrane cells (PEMFCs). In this study, sPEEK was used as polymer matrix for preparation nanocomposite electrolyte membranes by dispersing an organo-silica layered material properly functiona...
Compared to the common selective laser sintering (SLS) manufacturing method, fused deposition modeling (FDM) seems to be an economical and efficient three-dimensional (3D) printing method for high temperature polymer materials in medical applications. In this work, a customized FDM system was developed for polyether-ether-ketone (PEEK) materials printing. The effects of printing speed, layer th...
Stress shielding is a well-known failure factor in hip implants. This work proposes a design concept for hip implants, using a combination of metallic stem with a polymer coating (polyether ether ketone (PEEK)). The proposed design concept is simulated using titanium alloy stems and PEEK coatings with thicknesses varying from 100 to 400 μm. The Finite Element analysis of the cancellous bone sur...
Preparation Methods for Improving PEEK's Bioactivity for Orthopedic and Dental Application: A Review
There is an increased interest in the use of polyether ether ketone (PEEK) for orthopedic and dental implant applications due to its elastic modulus close to that of bone, biocompatibility, and its radiolucent properties. However, PEEK is still categorized as bioinert due to its low integration with surrounding tissues. Many studies have reported on methods to increase the bioactivity of PEEK, ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید