Sudden water inrush has been a deadly killer in underground engineering for decades. Currently, especially in developing countries, frequent water inrush accidents still kill a large number of miners every year. In this study, an approach for predicting the probability of fault-induced water inrush in underground engineering using the adaptive neuro-fuzzy inference system (ANFIS) was developed....
This paper describes the reduced capacity of the inrush current suppressor using a matrix converter (MC) in a large-capacity wind power generation system (WPGS) with two squirrel-cage induction machines (SCIMs). These SCIMs are switched over depending on the wind speed. The input side of the MC is connected to the source in parallel. The output side of the MC is connected in series with the SCI...
This paper will propose a cascade of minimum description length criterion with entropy approach along with artificial neural network (ANN) as an optimal feature extraction and selection tool for a wavelet packet transform based transformer differential protection. The proposed protection method provides a reliable and computationally efficient tool for distinguishing between internal faults and...
usually both ends of a transformer winding are at the same side of the magnetic core. with this arrangement there are automaticaly the same number of the turns for each winding in both core windows next to the middle leg of a three phase three leg core type transformer. contrary to this arrangement it is possible to put the two ends of a winding at the different sides of the core. in this case ...
internal turn-turn faults (ttf) are the most common failures in power transformers, which could seriously reduce their life expectancy. although common protection schemes such as current-baseddifferential protection are able to detect some of the internal faults, some other minor ones (such as ttfs andshort circuit near the neutral point) cannot be detected by such schemes. likewise, these rela...
Knowledge about the magnetic quantities in a magnetic circuit is always of great interest. On the one hand, this information is needed for the simulation of a transformer. On the other hand, parameter studies are more reliable, if the magnetic quantities are derived from a well established model. One possibility to model the 3-phase transformer is by using a magnetic equivalent circuit (MEC). T...
rotection schemes employing the differential relaying principle exhibit certain limitations in applications with power transformers. This is because the detection of a differential current does not clearly distinquish between internal faults and other possible conditions. Among the phenomena most likely to upset the current balance and cause the relay to malfunction are inrush magnetizing curre...
Inrush current with high amplitude is generated when the transformer energized. On one hand, it will have a negative impact on safety of itself, and even cause relay protection to malfunction. other may reduce operation speed there slight fault because restraint criteria. Both aspects affect grid security. Based generation mechanism inrush current, this paper proposes an reduction strategy that...