نتایج جستجو برای: nernstian response
تعداد نتایج: 977441 فیلتر نتایج به سال:
A PVC membrane sensor for the selective determination of mebendazole (MBZ) was fabricated. The sensor is based on an ion association of MBZ with silicotungstic acid (STA) as ion pair and bis(2-ethylhexyl)phthalate (BEP) as the plasticizing agent in a PVC matrix. The sensor showed a linear response for MBZ for a concentration range 1.0x10(-6)-5.0x10(-2) M with a Nernstian slope of 55.8 mV/decade...
A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response tim...
The effect of a specifically adsorbed ion, phosphate, on the electrochemical response and adsorption properties of nanocrystalline TiO2 is examined. Phosphate is known to affect the ú potential, as measured by electrophoretic mobility, by changing the charge of the oxide surface. The adsorption of a cationic probe molecule, thionine, onto TiO2 was monitored with an in-situ cell using UV-vis spe...
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two mont...
In this study, a potentiometric sensor composed of palm shell activated carbon modified with trioctylmethylammonium thiosalicylate (TOMATS) was used for the potentiometric determination of mercury ions in water samples. The proposed potentiometric sensor has good operating characteristics towards Hg (II), including a relatively high selectivity; a Nernstian response to Hg (II) ions in a concent...
A synthesized bis(dibenzoylmethanato)Co(II) complex (Co(DBM)(2)), has been used as a ionophore for the preparation of a new perchlorate ion-selective electrode. The electrode exhibits a Nernstian response over the perchlorate concentration range of 8.0x10(-7)-1.0x10(-1)M with a slope of 60.3+/-0.5 mV per decade of concentration. The limit of detection as determined from the intersection of the ...
A new modified palm shell activated carbon paste electrode based on 1,13-Bis(8-quinolyl)-1,4,7,10,13-pentaoxatridecane, 8,8-(1,4,7,10,13-Pentaoxatridecylene)-diquinoline (Kryptofix5) and plasticizing agent was prepared and studied as Hg selective electrode. The best performance was observed with the electrode composition having the ionophore-palm shell activated carbon-plasticizer composition 1...
Two novel polymeric membrane sensors for the analysis of Pb(II) have been developed based on two therapeutic drugs, thiopental (TP) and phenytoin (PT) as two new ionophores and potassium tetrakis(p-chlorophenyl) borate (KTpClPB) as a lipophilic additive, in plasticized PVC membranes. The sensors show a Nernstian response for Pb(II) ions over the wide concentration ranges of 1×10(-2) - 7×10(-6) ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید