نتایج جستجو برای: modular stem

تعداد نتایج: 323525  

2003
Ali Farghaly Jean Senellart

SYSTRAN started the design and the development of Arabic, Farsi and Urdu to English machine translation systems in July 2002. This paper describes the methodology and implementation adopted for dictionary building and morphological analysis. SYSTRAN’s IntuitiveCoding® technology (ICT) facilitates the creation, update, and maintenance of Arabic, Farsi and Urdu lexical entries, is more modular an...

Journal: :Molecular bioSystems 2012
Bin Xue Christopher J Oldfield Ya-Yue Van A Keith Dunker Vladimir N Uversky

Induced pluripotent stem (iPS) cells can be obtained from terminally differentiated somatic cells by overexpression of defined sets of reprogramming transcription factors. These protein sets have been called the Yamanaka factors, namely Sox2, Oct3/4 (Pou5f1), Klf4, and c-Myc, and the Thomson factors, namely Sox2, Oct3, Lin28, and Nanog. Other sets of proteins, while not essential for the format...

Journal: :Acta orthopaedica Belgica 2011
Bhavuk Garg Ravi Mittal Shishir Rastogi

Fracture of the femoral prosthesis neck following total hip arthroplasty is not common. We report a case of femoral prosthesis neck fracture in an adult male patient following modular, uncemented total hip arthroplasty. This case report further emphasizes the importance of the potentially high loading situation in the prosthetic femoral neck. On the other hand, the occurrence of a femoral prost...

2017
Adam I. Edelstein Duy L. Phan Scott M. Sporer

We report a case of bead shedding from a cylindrical extensively porous-coated cementless femoral component with concomitant taper corrosion at the modular head-neck junction of a metal-on-polyethylene total hip prosthesis. The patient presented with chronic thigh pain 4 years after primary total hip arthroplasty, and radiographs revealed significant osteolysis and metallic debris around the fe...

Journal: :Journal of the College of Physicians and Surgeons--Pakistan : JCPSP 2013
Ahsan Javed Butt Aamir Hassan Shaikh Hugh U Cameron

Knee revision using constrained implants is associated with greater stresses on the implant and interface surfaces. The present report describes a case of failure of the screw coupling between the stem and the femoral component. The cause of the failure is surmised with outline of the treatment in this case with extensive femoral bone loss. Revision implant stability was augmented with the use ...

2012

Development of the Stanmore hip system Following its development at the Department for Biomedical Engineering, Royal National Orthopaedic Hospital Stanmore the Stanmore stem was first implanted in 1973. The original design was manufactured from cast CoCr alloy (AliviumTM) which was supplemented by a forged titanium alloy (TivaloyTM) version in 1979. At this time both the CoCr and titanium alloy...

2016
Jemin Yi Kye Young Han Young Jun Nam Keun Woo Kim

PURPOSE This study aimed to investigate the outcomes of modular neck-utilization in primary total hip arthroplasty (THA). MATERIALS AND METHODS Thirty patients (34 hips) who had modular stem THA between April 2011 and January 2013 were evaluated. There were 19 men and 11 women with a mean age of 61.2 years at the time of surgery. There were 20 cases of osteonecrosis of femoral head, 7 cases o...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید