نتایج جستجو برای: modified carbon nano tube electrode

تعداد نتایج: 707968  

The present study examines a new dopamine sensor based on Alumina nanoparticles modified carbon paste electrode (Al2O3NPsCPE). Moreover, the present study focuses on the electrochemical act of the Al2O3NPsCPE for the detection of dopamine by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). There is also a focus on the specification of the prepared modified electrode by electroc...

Mirzazadeh Jalil Sayed Mahdi Golabi,

A thin film of epinephrine (EP) was electrochemically deposited on the surface of glassy carbon electrode previously activated in NaHCO3 solution. The cyclic voltammograms of the modified electrode indicate that the surface confined EP are strongly dependent on the solution pH, as expected for quinone/hydroquinone functionalities. The EP-modified glassy carbon electrode exhibited...

Abbas Afkhami, Atousa Bahiraei Mahdi Moradi Tayyebeh Madrakian,

In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...

Journal: :journal of physical & theoretical chemistry 2010
navid nasirizadeh mohammad saber tehrani m. reza. shishehbore ah karimi mohammad. a. shirgholami

a new hydroxylamine sensor has been fabricated by immobilizing oxadiazol denvative at the surface ol aglassy carbon electrode (gce) modified by multi-wall carbon nanotube (mivcnt). the adsorbed thin illms oroxadiazol derivative on the mwcnt modified gce show a pair of peaks with surface confined characierisnus.the oxadiazol derivative mwcni (omwcnt) modified gce shows highly catalytic activity ...

Journal: :physical chemistry and electrochemistry 0

the electrochemical behavior of a modified carbon paste electrode (mcpe) with n,n′ethylenbis(salicylideneiminato)copper(ii) complex ([cu(ii)-salen]) was investigated as a newsensor for cystein. the britton-robinson buffer with ph 5, 10% modifier in electrode, potentialscanning rate of 20 mvs-1 and puls height of 50 mv were used as the optimum condition for thedetermination of cysteine using car...

Journal: :physical chemistry and electrochemistry 0
elham eslami department of chemistry, kazerun branch, islamic azad university, kazerun, iran fatemeh farjam department of chemistry, marvdasht branch, islamic azad university, marvdasht, iran

we used an effective electrochemical sensor for the determination of imipramine at ph 7.2 using a carbon nanocomposite electrode. the electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. the high sensitivity of 1.714 μa (μm)-1, two linear calibration ranges of 0.1–2 μm and 2-40 μm, and detection limit of 19 nm were achieved. the relati...

A. Benvidi H. Kholghi H. Naeimi M. A. Sheikh-Mohseni M. Mazloum-Ardakani,

In this paper, a nanostructured modified electrode was fabricated by incorporating of 2,2′-[1,9-nonanediylbis(nitriloethylidyne)]-bis-hydroquinone (NNH) as a newly synthesized modifier and TiO2 nanoparticles to the carbon paste (MTCPE) and then was used for the electroanalysis of epinephrine (EP). The electrochemical studies were carried out by using cyclic voltammetry, chronoamperom...

Elham Eslami, Fatemeh Farjam

We used an effective electrochemical sensor for the determination of imipramine at pH 7.2 using a carbon nanocomposite electrode. The electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. The high sensitivity of 1.714 μA (μM)-1, two linear calibration ranges of 0.1–2 μM and 2-40 μM, and detection limit of 19 nM were achieved. The relati...

Journal: Journal of Nanoanalysis 2017
Ali Asghar Pasban, Elham Hossein Nia Masoumeh Piryaei,

Electrochemical behaviour of acetaminophen at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compared to other electrodes. Comparing the responses of the MWCNT/TiO2/GCE with that obtained at the...

2011
Li Zhang Feifei Yuan Xiaohu Zhang Liming Yang

BACKGROUND The detection of hydrogen peroxide (H2O2) and nitrite ion (NO2-) is of great important in various fields including clinic, food, pharmaceutical and environmental analyses. Compared with many methods that have been developed for the determination of them, the electrochemical detection method has attracted much attention. In recent years, with the development of nanotechnology, many ki...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید