نتایج جستجو برای: membrane electrode
تعداد نتایج: 449061 فیلتر نتایج به سال:
A physic-mathematical model has been developed that is suitable for biosensors incorporating membranes and bisubstrate enzymes. The set of equations regarding the transport of reactants across the membrane, the bisubstrate enzymatic reaction, back diffusion of reactants and reaction products, are written down and simultaneously solved and transient response of the electrode is determined as...
We found that dibenzo-18-crown-6 (DB18C6) can be used as an ionophore to make a tin (II)-ionselectivemembrane electrode. The electrode exhibits a near Nernstian response for Sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27.5 ± 0.6 mV per concentration decadein an acidic solution (pH=1). The limit of detection was 8.0× 10-7 M. It has a response time of < 20s an...
در این پایان نامه جهت اندازه گیری پتانسیومتری کاتیونهای سرب pb2+ و نیکلni2+ ، الکترود یون گزین غشایی مبتنی بر پلی وینیل کلرید (pvc) و الکترودهای خمیر کربن با استفاده از دو یون دوست جدید به همراه نرم کننده و افزودنیهای یونی طراحی، ساخت و مورد بررسی قرار گرفت. در تهیه الکترود یون گزین سرب از لیگاند n,n بیس( سالیسیلیدین) 1و6 دی آمینو هگزان (nsah) در ترکیب الکترود خمیر کربنی استفاده شد. الکترود ف...
چکیده ندارد.
الکترود یون گزین حساس به داروی آتنول بر پایه کمپلکس تجمع یونی آتنولول فسفوتنگستات در یک غشای pvc و نرم کننده غشاء استوفنون طراحی و ساخته شد. اثر ترکیب غشا دما زمان آماده سازی الکترود ph محلول آزمایشی و یون های مزاحم برعملکرد الکترود مورد بررسی قرار گرفت. برگشت پذیری گزینش پذیری و زمان پاسخ الکترود نیز مطالعه شد. الکترود یون گزین مربوطه پاسخ نرنستی در گستره غلظتی وسیع 10*1 به توان 2- و 10*1 به ت...
در این کار تحقیقاتی یک حسگر پتانسیومتری بر پایه پلیمرهای قالب ملکولی (mips) طراحی و ساخته شده و برای تشخیص و اندازه گیری ترکیب 2-آمینوپیریدین به کار گرفته شده است. یون فعال مورد اندازه گیری در واقع 2- آمینوپیریدین به طور مثبت باردار شده می باشد. برای تشکیل این جزء یونی اندازه گیری ها در یک محلول بافری با 5/4 انجام گرفته که در این ph 2-آمینوپیریدین به طور غالب تک پروتونه می باشد. در این شرایط پت...
Here, we report on a new solvent polymeric membrane electrode incorporating thermoresponsive poly(N-isopropylacrylamide) (PIPA) as a polymer with the lower critical solution temperature (LCST) of ca. 32 °C. The response of the solvent polymeric membrane electrode to the ions changes at 25 and 40 °C. Pulsed NMR analyses demonstrated the novel effects of the LCST behaviour on the potentiometric p...
A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...
In the present study, a step by step process was applied to synthesize bimetallic electrocatalyst (Ru and Pt on VulcanXC-72R). This process can reduce the amount of platinum and increase the gas diffusion electrode (GDE) performance in the cathodic reaction of polymer electrolyte membrane fuel cells (PEMFCs). Using the impregnation by hydrothermal synthesis method, a series of electrocatalysts ...
Molecular Model and Structural Stability Study of a Nafion Ionomer-Based Membrane Electrode Assembly
One of the most important parts of a polymer electrolyte membrane fuel cell (PEMFC) is the membrane electrode assembly (MEA). However, the delamination between the membrane and electrode layers, induced by uneven distribution of internal stress and stress concentration due to the inconsistent water and thermal expansion properties, greatly reduces the PEMFC durability. Based on the data from th...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید