نتایج جستجو برای: maximum skin dose
تعداد نتایج: 769272 فیلتر نتایج به سال:
Introduction: Due to the prevalence of skin problems in patients after radiotherapy, skin dose measuring is importance. Content: Skin in vivo dosimetry means measuring the patient's (or phantom) skin dose during radiotherapy. According to the ICRP 59, the dose at the depth of 0.07 mm is known as a skin dose. The most radiosensitive epidermis cells are located...
The purpose of this study was to compare dosimetric parameters of treatment plans among four techniques for preoperative single-fraction partial breast radiotherapy in order to select an optimal treatment technique. The techniques evaluated were noncoplanar 3D conformal radiation therapy (3D CRT), noncoplanar intensity-modulated radiation therapy (IMRTNC), coplanar IMRT (IMRTCO), and volumetric...
Background: Best dose distribution in target volume and control of Organ at Risk (OAR) dose are the two main goals in brachytherapy. Materials and Methods: In this study in vivo dosimetry in 4 rectal points was performed by Transillumination Dosimeter (TLD) s and the measured doses were compared in different patients. One point was reported to have the maximum dose in each patient and the very ...
PURPOSE Doxorubicin chemomyectomy presently represents the only permanent, nonsurgical treatment for blepharospasm and hemifacial spasm. The major deterrent to an otherwise extremely effective treatment protocol is the development in patients of localized inflammation, discomfort, and skin injury over the injection site. As a potential alternative therapy, Doxil (Sequus, Menlo Park, CA), a lipo...
Background: Skin cancer can be treated by various methods. Electron radiotherapy has been a useful therapeutic modality in the treatment of skin cancers in areas which are difficult to cure by other methods. Depth dose distribution of 166Ho using VARSKIN2 code is presented in this work. Material and Methods: Depth dose distribution of 166Ho was calculated, using VARSKIN2 code by adding...
For 318 patients in 8 different Belgian hospitals, the entire skin-dose distribution was mapped using a grid of 70 thermoluminescence dosimeters per patient, allowing an accurate determination of the maximum skin dose (MSD). Dose-area product (DAP) values, exposure parameters and geometry, together with procedure, patient and cardiologist characteristics, were also registered. Procedures were d...
Introduction: Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Operating procedures for total skin electron irradiation and its dosimetry vary in different radiation therapy centers in the world. In this article, validation of TSET techniq...
Purpose: Acuros XB (AXB) dose calculation algorithm is available for external beam photon dose calculations in Eclipse treatment planning system (TPS). The AXB can report the absorbed dose in two modes: dose-to-water (Dw) and dose-to-medium (Dm). The main purpose of this study was to compare the dosimetric results of the AXB_Dm with that of AXB_Dw on real patient treatment plans. Methods: Four ...
When the planning target volume (PTV), extends close to or beyond the skin, inverse-planned intensity-modulated radiotherapy can boost the fluence from tan- gential angles to superficial parts of the PTV due to the buildup effect. This can result in significant regions of high dose upon a small movement in the patient's position. We analyzed different methods of reducing this effect in the Tomo...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید