نتایج جستجو برای: location genetic algorithms monte carlo simulation

تعداد نتایج: 1641746  

Journal: :Applied Psychological Measurement 1983

Journal: :iranian journal of medical physics 0
asghar mesbahi department ofmedical physics, medical school, tabriz university of medical sciences,,tabriz, iran. 2- department ofradiation oncology, imam hospital, tabriz, iran. ismail zergoug 3-department of radiotherapy, emir abdelkaderanti-cancer center, oran, algeria

introduction radiotherapy with small fields is used widely in newly developed techniques. additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. in the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against monte carlo method. materials and methods siemens once or linea...

2005
Charles J. Geyer

Markov chain Monte Carlo (e. g., the Metropolis algorithm and Gibbs sampler) is a general tool for simulation of complex stochastic processes useful in many types of statistical inference. The basics of Markov chain Monte Carlo are reviewed, including choice of algorithms and variance estimation, and some new methods are introduced. The use of Markov chain Monte Carlo for maximum likelihood est...

2007
Leif Andersen

Stochastic volatility models are increasingly important in practical derivatives pricing applications, yet relatively little work has been undertaken in the development of practical Monte Carlo simulation methods for this class of models. This paper considers several new algorithms for time-discretization and Monte Carlo simulation of Heston-type stochastic volatility models. The algorithms are...

Journal: :iranian journal of medical physics 0
zohreh dehghannia rostami graduated m.sc. student of nuclear physics, physics dept., kn toosi university of technology, tehran, iran. seyed farhad masoudi associate professor, physics dept., kn toosi university of technology, tehran. iran somayeh asadi graduated m.sc. student of nuclear physics, physics dept., kn toosi university of technology, tehran, iran.

introduction: in this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125i and 103pd. material and methods: the simulation of the two phantoms were performed in the mcnp-4c code and by using the geometry of a three-dimensional eye, differen...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2009
bahman abdolhamidzadeh davood rashtchian elham ashuri

some of the most destructive accidents of 1980s and 90s which occurred in process industries were domino accidents. although domino accidents are among the most destructive industrial accidents, there are not much pioneering works done on quantification of them. the analytical formulation of the domino accidents is usually complex and need a deep knowledge of probability rules. even if the case...

Journal: :journal of industrial engineering, international 2011
h babaei k shahanaghi a bakhsha

in this paper, we focus on a continuously deteriorating critical equipment which its failure cannot be measured by cost criterion. for these types of systems like military systems, nuclear systems, etc it is extremely important to avoid failure during the actual operation of the system. in this paper we propose an approach which constrains failure probability to a pre-specified value. this valu...

Journal: :علوم و تکنولوژی پلیمر 0
محمد نجفی حسین روغنی ممقانی مهدی سلامی کلجاهی وحید حدادی اصل

atom transfer radical polymerization (atrp) of styrene was carried out at 105°c and a monte carlo simulation was employed to model the system. the variations of monomer conversion, the initiator concentration, average molecular weight, and molecular weight distribution were evaluated as the reaction proceeded. according to the results obtained, for similar reaction time, monomer conversion is h...

Journal: :iranian journal of radiation research 0
m. momennezhad nuclear medicine research center, emam reza hospital, mashhad university of medical sciences, mashhad, iran m.t. bahreyni toosi medical physics research center, mashhad university of medical sciences, mashhad, iran r. sadeghi nuclear medicine research center, emam reza hospital, mashhad university of medical sciences, mashhad, iran h. gholamhoseinian department of medical physics, medical school, mashhad university of medical sciences, mashhad, iran sh. nasseri department of medical physics, medical school, mashhad university of medical sciences, mashhad, iran

background: the presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. material and methods: in this study the mcnp-4c monte carlo code was used to simulate the 9 mv photon beam generated by a linear accelerator. upon getting a good agreement between the ...

Journal: :iranian journal of science and technology (sciences) 2013
a. shirani m. h alamatsaz

exposure buildup factors have been calculated by monte carlo method for point isotropic gamma ray sources, penetrating a two-layer spherical shield of water surrounded by lead, and the effect of bremsstrahlung radiation on buildup factors has, in particular, been investigated, the results of which are in good agreement with previous works. the buildup factors were then calculated for various co...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید