نتایج جستجو برای: ion selective electrode
تعداد نتایج: 450039 فیلتر نتایج به سال:
A PVC membrane Ni(II) ion selective electrode has been constructed using (1E,2E)-bis(2-aminophenyl)N'1,N'2-dihydroxyethanebis as membrane carrier. The electrode exhibited a goodpotentiometric response for Ni(II) over a wide concentration range 1.0×10-4 to 1.0×10-1M with aslope of 29.4±0.5 mV/decade a and a working pH range of 6.5-9.0. It had a fast response time of≤20s. The best performance was...
A new plastic membrane ion-selective electrode for determination of metformin hydrochloride has been prepared, after forming the ion pair of metformin hydrochloride with sodium tetraphenylborate. Dioctyl phthalate and sodium tetraphenylborate were used as plasticizer and counter ion respectively. The electrode exhibited a linear potential response in the concentration range 1 × 10 M–1 × 10 M wi...
A cobalt(II) derivative was used as a suitable ionophore for the preparation of a polymeric membrane nitrite-selective electrode. The electrode reveals a Nemstian behavior over a very wide NO2- ion concentration range (1.0 x 10(-6)-1.0 x 10(-1) M) and a very low detection limit (5.0 x 10(-7) M). The potentiometric response is independent of the pH of solution in the pH range 4.0-9.5. The electr...
A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...
Dimethyl amino ethyl chloride hydrochloride (DMC) is a primary material of fuel of dimethyl amino ethyl azide (DMAZ) that is a good alternative for hydrazine derivatives in the aerospace industry. Some amount of unreacted DMC remains in the wastewater in production processes of DMAZ (95% wt.) that due to toxicity and corrosion effect of DMC, determination of this compound in DMAZ waste is ine...
چکیده ندارد.
الکترود یون گزین حساس به داروی آتنول بر پایه کمپلکس تجمع یونی آتنولول فسفوتنگستات در یک غشای pvc و نرم کننده غشاء استوفنون طراحی و ساخته شد. اثر ترکیب غشا دما زمان آماده سازی الکترود ph محلول آزمایشی و یون های مزاحم برعملکرد الکترود مورد بررسی قرار گرفت. برگشت پذیری گزینش پذیری و زمان پاسخ الکترود نیز مطالعه شد. الکترود یون گزین مربوطه پاسخ نرنستی در گستره غلظتی وسیع 10*1 به توان 2- و 10*1 به ت...
در این کار تحقیقاتی یک حسگر پتانسیومتری بر پایه پلیمرهای قالب ملکولی (mips) طراحی و ساخته شده و برای تشخیص و اندازه گیری ترکیب 2-آمینوپیریدین به کار گرفته شده است. یون فعال مورد اندازه گیری در واقع 2- آمینوپیریدین به طور مثبت باردار شده می باشد. برای تشکیل این جزء یونی اندازه گیری ها در یک محلول بافری با 5/4 انجام گرفته که در این ph 2-آمینوپیریدین به طور غالب تک پروتونه می باشد. در این شرایط پت...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید