نتایج جستجو برای: inversion recovery

تعداد نتایج: 241145  

2003
Rangeet Bhattacharyya Anil Kumar

A new method of measuring long spin-lattice relaxation times (T1) is proposed. Being a single scan technique, the method is at least one order of magnitude faster than the conventional technique. This method (Single-Scan or Slice Selected Inversion Recovery or SSIR) relies on the slice selection technique. The method is experimentally verified and compared with the time taken by the conventiona...

2003
H. Kim A. Youssef

This paper proposes a bit error recovery method for Extended 2 Dimensional MMR coded bitstreams. When an error occurs in an MMR coded bitstream, the bitstream cannot be decoded correctly after the error point. To prevent losing valid information after an error, we developed an error recovery system that detects bit errors and applies bit-inversion to correct the errors. In case the bit-inversio...

2012
Monvadi B Srichai Ruth P Lim Narayan Lath James Babb Leon Axel Daniel Kim

Background Edema-sensitive T2-weighted cardiac magnetic resonance (CMR) based on fast spin-echo (FSE) imaging is a useful modality to detect acute myocardial injury. Conventional T2-weighted CMR uses three inversion-recovery (IR) pulses, the first two to null the blood signal, and the last one (STIR) to null fat signal, but suffers from reduced myocardial signal and signal dropout. We compared ...

2015
Nicholas Byrne Rene Botnar Tarique Hussain Stephen F Keevil Sarah Peel

Background The dual inversion recovery (dual IR) pulse sequence has recently been shown to improve blood suppression and infarct delineation in late gadolinium enhancement (LGE) images of myocardial infarction. This resulted in significantly lower inter-observer variability in manual outlining of scar and higher expert confidence in scar detection and transmurality when compared with convention...

2009
S. Datta J. S. Wolinsky P. A. Narayana

Introduction: Multiple sclerosis affects both white matter (WM) and gray matter (GM). Conventional MR imaging is widely used to assess T2 hyperintense lesions in WM. These techniques are suboptimal in detecting cortical lesions. Recently, double inversion recovery (DIR) and phase sensitive inversion recovery (PSIR) have been shown to increase the confidence with which cortical lesions can be vi...

Journal: :British heart journal 1983
K Miwa T Murakami H Kambara C Kawai

Sequential 12 lead electrocardiograms were recorded during angina pectoris induced by ergonovine maleate in 38 patients with variant angina. Transient U wave inversion was observed in 17 patients with ST segment elevation in anterior chest leads, but in only three of 21 patients with ST segment elevation in the inferior leads associated with right coronary artery spasm. In the 17, all of whom h...

Journal: :Magnetic resonance in medicine 2010
Ke Li Zhongliang Zu Junzhong Xu Vaibhav A Janve John C Gore Mark D Does Daniel F Gochberg

Inversion recovery sequences that vary the inversion time (t(i)) have been employed to determine T(1) and, more recently, quantitative magnetization transfer parameters. Specifically, in previous work, the inversion recovery pulse sequences varied t(i) only while maintaining a constant delay (t(d)) between repetitions. T(1) values were determined by fitting to a single exponential function, and...

2008
S. Walker-Samuel M. Orton L. C. Baker J. K. Boult S. P. Robinson

Introduction: Inversion recovery (IR) TrueFISP imaging sequences have recently been used to acquire dynamic contrast enhanced (DCE) MRI data due to their short acquisition time, sensitivity to changes in tissue longitudinal relaxation times and superior signal-to-noise characteristics [1]. Use of an inversion recovery preparation offers the ability to quantify relaxation time changes at each dy...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید