نتایج جستجو برای: impedance point
تعداد نتایج: 558549 فیلتر نتایج به سال:
High impedance fault (HIF) is a long standing problem which known by very complex phenomena, because of its distinctive characteristics asymmetry and nonlinearity behavior. Besides that, arc is the most serious problem which is mostly associated with high impedance fault, this arc is considered as a source of human life risks and fire hazardous, and additionally result in property damage. From ...
The isolated, ventilated and instrumented mouse lung preparation allows steady and pulsatile pulmonary vascular pressure-flow relationships to be measured with independent control over pulmonary arterial flow rate, flow rate waveform, airway pressure and left atrial pressure. Pulmonary vascular resistance is calculated based on multi-point, steady pressure-flow curves; pulmonary vascular impeda...
We compared spirometry (FEV1) and airway impedance (z) in the assessment of airway responsiveness to histamine. Airway impedance was measured by the oscillator technique during quiet breathing; both measurements were made twice after each increment of histamine during the challenge. Percentage change in impedance was related to percentage change in FEV1 according to: -delta z = 1.09-2.66 (delta...
Assessment of complex harmonic current contribution of each wind turbines at connection point of a wind farm to the grid (primary emission) is presented in this paper. Moreover, contribution of grid background harmonic voltage distortion on harmonic current distortion (secondary emission) of each turbine is also evaluated. Both assessments are represented based on primary and secondary transfer...
In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...
Impedance Cardiography (ICG) is a noninvasive technique for monitoring stroke volume, cardiac output and other hemodynamic parameters, which is based on sensing the change of thoracic electrical impedance caused by blood volume change in aorta during the cardiac cycle. Motion artifact and respiratory artifact can lead to baseline drift in ICG signal, particularly during or after exercise, which...
in this study, a novel variable impedance control for a lower-limb rehabilitation robotic system using voltage control strategy is presented. the majority of existing control approaches are based on control torque strategy, which require the knowledge of robot dynamics as well as dynamic of patients. this requires the controller to overcome complex problems such as uncertainties and nonlinearit...
The aim of this work was to develop a minimally invasive, impedance spectroscopy method as a novel process analytical technology for monitoring the freeze drying process. This involved the application of planar electrodes, mounted externally to a conventional glass freeze-drying vial, coupled to a high-impedance analyser. The pseudo-relaxation process arising from the composite impedance of the...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید